The performance of optical components can have significant dependence on polarization, as with the difference between TE and TM polarization in planar devices like AWG and SOA. Determination of the optical properties for the principal states of polarization can be needed, for instance to determine the polarization dependent wavelength of a bandpass filter. It can be complicated to adjust instrumentation to provide these polarization states. A fast and direct method to do this based on Mueller matrix analysis is described here. 02 | Keysight | Polarization-Resolved Measurements using Mueller Matrix Analysis Application Note
منابع مشابه
Double-pass axially resolved confocal Mueller matrix imaging polarimetry.
We present experimental depth-resolved complete polarization-sensitive measurements of a stack of linear retarders and glass plates by using what is to the best of our knowledge the first combination of a confocal imaging system with a complete Mueller matrix polarimeter. The axially resolved Mueller matrices were compared with a forward simulation, with good agreement.
متن کاملTowards Measurement of Polarization Properties of Skin using the Ellipsometry Technique
Introduction: The human skin is an active medium from the optical point of view. Therefore, the diagnostic and therapeutic techniques employing light are increasing. Current optical techniques are based on the measurement of the intensity of reflected absorbed or backscattered light from or within skin. Studies have shown that biological tissues, and in particular skin, demonstrate polarization...
متن کاملPolar decomposition of 3 x 3 Mueller matrix: a tool for quantitative tissue polarimetry.
The polarization properties of any medium are completely described by the sixteen element Mueller matrix that relates the polarization parameters of the light incident on the medium to that emerging from it. Measurement of all the elements of the matrix requires a minimum of sixteen measurements involving both linear and circularly polarized light. However, for many diagnostic applications, it ...
متن کاملTime-resolved switching analysis of a ferroelectric liquid crystal by snapshot Mueller matrix polarimetry.
An experimental snapshot Mueller matrix polarimeter based on wavelength polarization coding is used to get a time-resolved description of electric-field-induced fast transition within a ferroelectric liquid-crystal cell. The parameters extracted from experimental Mueller matrices are linked to the molecule director distribution to further determine the average trajectory and the collective beha...
متن کاملTwo-dimensional depth-resolved Mueller matrix of biological tissue measured with double-beam polarization-sensitive optical coherence tomography.
A double-beam polarization-sensitive system based on optical coherence tomography was built to measure the Mueller matrix of scattering biological tissue with high spatial resolution. The Jones matrix of a sample can be determined with a single scan and subsequently converted into an equivalent nondepolarizing Mueller matrix. As a result, the system can be used to measure the Mueller matrix of ...
متن کامل