A responsivity-based criterion for accurate calibration of FTIR emission spectra: identification of in-band low-responsivity wavenumbers.
نویسندگان
چکیده
Spectra measured by remote-sensing Fourier transform infrared spectrometers are often calibrated using two calibration sources. At wavenumbers where the absorption coefficient is large, air within the optical path of the instrument can absorb most calibration-source signal, resulting in extreme errors. In this paper, a criterion in terms of the instrument responsivity is used to identify such wavenumbers within the instrument bandwidth of two remote-sensing Fourier transform infrared spectrometers. Wavenumbers identified by the criterion are found to be correlated with strong absorption line-centers of water vapor. Advantages of using a responsivity-based criterion are demonstrated.
منابع مشابه
Responsivity-based criterion for accurate calibration of FTIR emission spectra: theoretical development and bandwidth estimation.
An analytical expression for the variance of the radiance measured by Fourier-transform infrared (FTIR) emission spectrometers exists only in the limit of low noise. Outside this limit, the variance needs to be calculated numerically. In addition, a criterion for low noise is needed to identify properly calibrated radiances and optimize the instrument bandwidth. In this work, the variance and t...
متن کاملA responsitivity-based criterion for accurate calibration of FTIR spectra: theoretical development and bandwidth estimation
An analytical expression for the variance of the radiance measured by Fourier-transform infrared (FTIR) emission spectrometers exists only in the limit of low noise. Outside this limit, the variance needs to be calculated numerically. In addition, a criterion for low noise is needed to identify properly calibrated radiances and optimize the instrument bandwidth. In this work, the variance and t...
متن کاملPre-Launch Absolute Spectral Flux Calibration
A common approach to pre-launch absolute spectral flux calibration of an instrument is to break the problem into two parts [1]. In the first part, the relative spectral responsivity (RSR) is determined in the laboratory, often by tuning a quasi-monochromatic source across the bandpass of the instrument. The result from this first part is a spectrum (for each pixel and each band) normalized at s...
متن کاملIlluminance Responsivity Calibration of Reference Photometers at the Nist Sircus and Scf Facilities
The illuminance responsivities of two transfer standard photometers have been directly determined from their spectral responsivity calibrations at two different calibration facilities of NIST. The main characteristics of the two photometers, and their calibrations are described. The spectral and broad-band (illuminance) responsivities measured at the two different facilities are compared. The t...
متن کاملEffect of temperature and activator molar of Na2O to SiO2 in the process of synthesis and microstructure of cement geopolymer
Inorganic polymers were synthesized from dehydroxylated aluminosilicate clay (metakaolinite) condensed with sodium silicate in a highly alkaline environment. The thermal treatment of aluminosilicate materials causes changes in their structure with an increase in the amorphous phase. For that kind of structural change XRD analysis is not appropriate, so those changes are currently assessed by in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 19 7 شماره
صفحات -
تاریخ انتشار 2011