E!ects of charge sharing in 3-D position sensitive CdZnTe gamma-ray spectrometers

نویسندگان

  • Z. He
  • W. Li
  • G. F. Knoll
  • D. K. Wehe
  • Y. F. Du
چکیده

Two 3-D position-sensitive semiconductor c-ray spectrometers operable at room temperature, have been fabricated using 1 cm3 cubic CdZnTe crystals. c-Ray spectra have been obtained from 11(x)]11(y)]20(z) voxels, each corresponding to &0.7]0.7]0.5 mm in the detector volume. Individual spectra from each of the 2420 voxels were corrected for electron trapping, di!erences in weighting potentials, and the gain variation of the readout circuitry. Energy resolutions of 1.70% (11.3 keV) FWHM and 1.84% (12.2 keV) FWHM were obtained at 662 keV from the combined output of the entire volume for single-pixel events. Charge sharing between neighboring pixels has been observed and the sizes of electron clouds are estimated from these experimental data. An understanding of electron cloud dimensions is important for the design of future detectors using pixellated electrodes. ( 2000 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of material uniformity using 3-D position sensitive CdZnTe gamma-ray spectrometers

We present results from two 1 cm3 CdZnTe gamma-ray spectrometers with full 3-D position sensitivity. To our knowledge, these are the "rst reported semiconductor spectrometers that provide independent spectral data for each of over 2000 volume elements. Energy resolutions of 1.5}1.6% FWHM and position resolutions of 0.7]0.7]0.5 mm were obtained at 662 keV gamma-ray energy from the central region...

متن کامل

3D position sensitive CdZnTe gamma-ray spectrometers – improved performance with new ASICs

A 3-dimensional position sensitive CdZnTe gamma-ray spectrometer based on VAS3.1/TAT3 ASICs was developed and tested. The 3-D CZT spectrometer employs a 1.5 × 1.5 × 1 cm CdZnTe crystal with 11 by 11 pixelated anodes wire-bonded to the readout electronics. The signals from the anode pixels and the cathode were both read out through the ASICs. The pixel position provides the lateral 2-D coordinat...

متن کامل

3-D position sensitive CdZnTe gamma-ray spectrometers

Two 3-D position-sensitive room temperature semiconductor c-ray spectrometers have been built using 1 cm3 cubic CdZnTe crystals. The lateral coordinates of c-ray interaction are obtained from the location of the 11(x)]11(y) pixellated anodes and the depth (z) is obtained from the ratio of the signals coming from the cathode and the anode. Energy spectra from 662keV incident c-rays have been col...

متن کامل

A Modeling Method to Calibrate the Interaction Depth in 3-D Position Sensitive CdZnTe Gamma-Ray Spectrometers

The gamma ray interaction depth in 3-D position scnsitive CdZnTe dctectors is currently determined by the pulse height ratio ofthe cathode signal to the anode pixel signal (CIA ratio). In expcriments with our 3-D CdZnTe dctectors, thc photopeak area as a fuuction of the CIA ratio deviates from the expected exponential attcnuation with depth. This indicatcs that the CIA ratio is not proportional...

متن کامل

Investigation of charge sharing among electrode strips for a CdZnTe detector

We have investigated charge sharing among the anode strips of a CdZnTe (CZT) detector using a 30μm collimated gamma-ray beam. We compared the laboratory measurements with the predictions from our modeling of the charge transport within the detector. The results indicate that charge sharing is a function of the interaction depth and the energy of the incoming photon. Also, depending on depth, a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999