Statistical-Based Approach for Extracting 3D Blood Vessels from TOF-MyRA Data

نویسندگان

  • M. Sabry Hassouna
  • Aly A. Farag
  • Stephen G. Hushek
  • Thomas Moriarty
چکیده

In this paper we present an automatic statistical intensity basedapproach for extracting the 3D cerebrovascular system from time-of-flight (TOF) magnetic resonance angiography (MRA) data. The voxels of the dataset are classified as either background tissues, which are modeled by a finite mixture of one Rayleigh and two normal distributions, or blood vessels, which are modeled by one normal distribution. We show that the proposed models fit the clinical data properly and result in fewer misclassified vessel voxels. We estimated the parameters of each distribution using the expectation maximization (EM) algorithm. Since the convergence of the EM is sensitive to the initial estimate of the parameters, a novel method for parameter initialization, based on histogram analysis, is provided. A new geometrical phantom motivated by a statistical analysis was designed to validate the accuracy of our method. The algorithm was also tested on 20 in-vivo datasets. The results showed that the proposed approach provides accurate segmentation, especially those blood vessels of small sizes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Statistical-Based Approach for Extracting 3D Blood Vessels from TOF-MRA Data

In this paper we present an automatic statistical intensity basedapproach for extracting the 3D cerebrovascular system from time-of-flight (TOF) magnetic resonance angiography (MRA) data. The voxels of the dataset are classified as either background tissues, which are modeled by a finite mixture of one Rayleigh and two normal distributions, or blood vessels, which are modeled by one normal dist...

متن کامل

Cerebrovascular segmentation from TOF using stochastic models

In this paper, we present an automatic statistical approach for extracting 3D blood vessels from time-of-flight (TOF) magnetic resonance angiography (MRA) data. The voxels of the dataset are classified as either blood vessels or background noise. The observed volume data is modeled by two stochastic processes. The low level process characterizes the intensity distribution of the data, while the...

متن کامل

Voxel-coding method for quantification of vascular structure from 3D images

ABSTRACT This paper presents an image processing method for information extraction from 3D images of vasculature. It automates the study of vascular structures by extracting quantitative information such as skeleton, length diameter, and vessel-to-tissue ratio for different vessels as well as their branches. Furthermore, it generates 3D visualization of vessels based on desired anatomical chara...

متن کامل

Contrast-enhanced MR angiography of intracranial giant aneurysms.

BACKGROUND AND PURPOSE Intravoxel phase dispersion and flow saturation often prevent adequate depiction of intracranial giant aneurysms on 3D time-of-flight (3D-TOF) MR angiography (MRA). Additional diagnostic difficulties may arise from T1 contamination artifact of an associated blood clot. Our aim was to assess whether contrast-enhanced MRA could improve the evaluation of giant aneurysms and ...

متن کامل

Extracting Vessel Centerlines From Retinal Images Using Topographical Properties and Directional Filters

In this paper we consider the problem of blood vessel segmentation in retinal images. After enhancing the retinal image we use green channel of images for segmentation as it provides better discrimination between vessels and background. We consider the negative of retinal green channel image as a topographical surface and extract ridge points on this surface. The points with this property are l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003