Impact of Different Personal Protective Clothing on Wildland Firefighters' Physiological Strain

نویسندگان

  • Belén Carballo-Leyenda
  • José G. Villa
  • Jorge López-Satué
  • Jose A. Rodríguez-Marroyo
چکیده

Wildfire firefighting is an extremely demanding occupation performed under hot environment. The use of personal protective clothing (PPC) is needed to protect subjects from the thermal exposure. However, the additional use of PPC may increase the wildland firefighters' physiological strain, and consequently limit their performance. The aim of this study was to analyze the effect of four different PPC on the physiological strain of wildland firefighters under moderate conditions (30°C and 30% RH). Eight active and healthy wildland firefighters performed a submaximal walking test wearing a traditional short sports gear and 4 different PPC. The materials combination (viscose, Nomex, Kevlar, P-140 and fire resistant cotton) used during the PPC manufacturing process was different. During all tests, to simulate a real scenario subjects wore a backpack pump (20 kg). Heart rate, respiratory gas exchange, gastrointestinal temperature, blood lactate concentration, perceived exertion and temperature and humidity underneath the PPC were recorded throughout tests. Additionally, parameters of heat balance were estimated. Wearing a PPC did not cause a significant increase in the subjects' physiological response. The gastrointestinal temperature increment, the relative humidity of the microclimate underneath the PPC, the sweat residue in PPC, the sweat efficiency, the dry heat exchange and the total clothing insulation were significantly affected according to the PPC fabric composition. These results suggest that the PPC composition affect the moisture management. This might be taken into account to increase the wildland firefighters' protection in real situations, when they have to work close to the flames.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of base layer materials on physiological and perceptual responses to exercise in personal protective equipment.

Ten men (non-firefighters) completed a 110 min walking/recovery protocol (three 20-min exercise bouts, with recovery periods of 10, 20, and 20 min following successive bouts) in a thermoneutral laboratory while wearing firefighting personal protective equipment over one of four base layers: cotton, modacrylic, wool, and phase change material. There were no significant differences in changes in ...

متن کامل

Moisture effects in heat transfer through clothing systems for wildland firefighters.

Wildland firefighters work in unfavourable environments involving both heat and moisture. Moisture in clothing systems worn by wildland firefighters may increase or decrease heat transfer, depending on its source and location in the clothing system, location on the body, timing of application and degree of sorption. In this experiment, 4 outerwear/underwear combinations were exposed to 1 of 5 d...

متن کامل

Perceptual and physiological heat strain: examination in firefighters in laboratory- and field-based studies.

Firefighting demands performing heavy muscular work under adverse and potentially dangerous conditions. Although the physiological and psychological responses to simulated firefighting activities have been described, the heat strain has not been characterised using standardised indices of exercise-heat strain. The purpose of the study is to describe the physiological and perceptual strain assoc...

متن کامل

Firefighter's personal protective equipment and the chronotropic index.

UNLABELLED The purpose of this study was to investigate the effects of personal protective equipment (PPE) on cardiovascular and metabolic responses during incremental exercise, and to determine if PPE affects the relationship between heart rate (HR) and oxygen uptake when expressed as the chronotropic index (CI). Ten male participants performed graded exercise tests under three conditions: con...

متن کامل

بررسی یک استراتژی مداخله‌ای خنک‌کننده‌ برای کاهش استرین حرارتی ناشی از لباس حفاظتی آتش‌نشانان

Introduction: Protective clothes are among the basic needs of firefighters against their occupational risks. Combination of heat stress effects caused by muscle activation and protective clothing, result in a high level of strain in the regulating system of body temperature. The aim of this study was to evaluate the practical cooling method of hand and forearm immersion in water. Methods: In...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2017