Four- to six-year follow-up of primary THA using contemporary titanium tapered stems.

نویسندگان

  • Devon D Goetz
  • Arun Reddy
  • John J Callaghan
  • David W Hennessy
  • Nicholas A Bedard
  • Steve S Liu
چکیده

Tapered cementless femoral components have been used in total hip arthroplasty constructs for more than 20 years. In the past 5 to 10 years, these stems have gained popularity in the United States. The purpose of this study was to evaluate the results of the authors’ initial experience using a contemporary tapered, proximally porous-coated, titanium femoral component at 4 to 6 years of follow-up. Eighty-eight patients underwent 100 total hip arthroplasties using the Summit stem (DePuy, Warsaw, Indiana) and a cementless acetabular component. Average age at the time of surgery was 61.6 years. Patients were prospectively followed for 4 to 6 years or until death. Patients were evaluated clinically using Harris Hip Scores and the need for revision. Radiographs were evaluated for femoral loosening and osteolysis. At final follow-up, no hips had been revised for femoral or acetabular loosening. Two hips required revision for dislocation and 1 for early femoral fracture. Bony ingrowth was seen in all but 2 femoral components. There was 1 instance of proximal femoral osteolysis and none distally on radiographs (cross-linked polyethylene was used in 73% of cases). There were 2 cases of severe stress shielding. One percent of cases had an early fracture (too tight) and 1% subsided without ingrowth (too loose). One patient reported significant thigh pain that did not limit activity. At final follow-up, the Summit femoral component demonstrated durable results at 4 to 6 years. Stability of the implant without femoral fracture is paramount.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Medium-term outcome of titanium uncemented stems in revision total hip arthroplasty.

PURPOSE To assess the medium-term outcome of titanium uncemented modular tapered stems in revision total hip arthroplasty (THA). METHODS A questionnaire was mailed to 421 patients who underwent revision THA using a titanium uncemented modular tapered stem. 66 of whom underwent re-revision THA. The questionnaire was composed to reveal the Charnley classification, the modified 12-item Oxford hi...

متن کامل

Stubby stems: good things come in small packages.

Standard-length porous-coated tapered femoral stems perform exceedingly well in primary total hip arthroplasty (THA) at long-term follow-up. Nevertheless, there are multiple reasons to strongly consider the relatively new concept of short tapered stems. First, there is already a wide variation in the lengths of "standard" components and the ideal length is unknown. The goal of tapered stems is ...

متن کامل

Seven-year Results of a Tapered, Titanium, Hydroxyapatite-Coated Cementless Femoral Stem in Primary Total Hip Arthroplasty

BACKGROUND Aseptic loosening of cemented hip prostheses is recognized as a long-term problem, and especially in males and younger patients. Much energy has been focused on developing new prostheses that are designed for cementless fixation. We evaluated the performance of and periprosthetic bone response to a tapered, titanium, hydroxyapatite (HA)-coated femoral hip prosthesis at a minimum of 7...

متن کامل

Primary Total Hip Arthroplasty Using Summit® Stems in Korean: Minimum Four-year Follow-up

Purpose The aim of this study was to assess the mid-term results of primary cementless total hip arthroplasty (THA) using Summit® stems. Materials and Methods One hundred twenty-eight arthroplasties in 121 patients who were performed THA from December 2004 to March 2013, were reviewed retrospectively a minimum of 4 years follow-up (mean age, 60.3 years; mean postoperative follow up period, 86...

متن کامل

Radiographic evaluation of cementation technique using polished, conical, triple-tapered femoral stem in hip arthroplasty☆

OBJECTIVE To radiographically evaluate the quality of cementation and implantation technique using a polished, triple-tapered femoral stem in total hip arthroplasty (THA). METHOD Retrospective study with radiographic evaluation of 86 hips in 83 patients who underwent to primary THA with the triple-tapered cemented femoral stem C-Stem (DePuy Orthopedics, Warsaw, Indiana). Cases with at least o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 36 12  شماره 

صفحات  -

تاریخ انتشار 2013