Sorin Solo stentless valve: extended adaptability for sinotubular junction mismatch.
نویسندگان
چکیده
Stentless valve continence is affected by the implantation technique, annular symmetry and dilatation of the sinotubular junction. We tested in vitro how the Sorin Solo stentless pericardial valve adapts to a slightly dilated sinotubular junction. Stentless Sorin Solo aortic valves (25 mm) were sutured into a 32-mm Valsalva graft suspending the commissures into the expandable region of the graft. The neo-aortic root was pressurized and sinotubular junction size progressively decreased by wrapping the neocommissural ridge with Dacron rings. Direct endoscopic view and ultrasound imaging were used to observe geometry and morphology of leaflets, regurgitation, height and level of leaflets coaptation. Fresh porcine valves of the same annular size were used as controls. Solo valves had mild regurgitation at baseline, became continent at 32 mm sinotubular junction size and remained continent at any size of reduction, with optimal coaptation height and level. Porcine valves had severe regurgitation at baseline, became continent at 30 mm and showed mild insufficiency and reduction of the coaptation level at a sinotubular junction of 28 mm. The Solo valve prevents residual valve regurgitation for a wider range of sinotubular junction mismatch when compared with natural porcine valves. This extended tolerance to sinotubular junction mismatch suggests a safe use of stentless valves even in suboptimal geometry roots.
منابع مشابه
The Sorin Freedom SOLO stentless aortic valve: easier implantation technique with potentially less risk of complications.
Aortic valve replacement by bioprosthesis is increasingly being used. Among these, stentless bioprosthesis is becoming a valid choice due to its potential hemodynamic improvement. The Sorin Freedom SOLO stentless aortic valve (FS) (Sorin Biomedica Cardio, Saluggia, Italy) is widely used, with initial and midterm promising results. It is designed to be deployed in a straightforward manner in the...
متن کاملIn-vitro study on the relationship between progressive sinotubular junction dilatation and aortic regurgitation for several stentless aortic valve substitutes.
OBJECTIVE Stentless aortic valves are widely used due to their excellent hemodynamic properties. However, if the subcoronary implantation technique is used later dilatation of the sinotubular junction (STJ) can cause regurgitation. The aim of the study was to determine the dilatation tolerance of two commercially available stentless xenografts and fresh aortic and pulmonary roots against such d...
متن کاملThe Freedom SOLO bovine pericardial stentless valve: Single-center experience, outcome and long-term durability
OBJECTIVES: We report our institutional experience and long-term results with the Sorin Freedom SOLO bovine pericardial stentless bioprosthesis. METHODS: Between January 2005 and November 2009, 149 patients (mean age 73.6±8.7 years, 68 [45.6%] female) underwent isolated (n=75) or combined (n=74) aortic valve replacement (AVR) using the SOLO in our institution. Follow-up was 100% complete with a...
متن کاملStentless aortic valves. Current aspects
The design of stentless valve prostheses is intended to achieve a more physiological flow pattern and superior hemodynamics in comparison to stented valves. First - generation stentless bioprosthesis were the Prima valve, the Freestyle valve and the Toronto stentless porcine valve. The second generation of stentless valves, as the Super stentless aortic porcine valve, need only one suture line....
متن کاملOperative technique and early hemodynamic results with the Freedom Solo valve.
BACKGROUND AND AIM OF THE STUDY Stentless aortic valve prostheses usually require two separate suture lines. The Freedom Solo valve (Sorin Group, Saluggia, Italy), by using a minimized implantation technique, requires only a single running suture line of 4-0 polypropylene. Herein are reported the surgical experience and early hemodynamic results obtained with this new valve. METHODS Following...