The Importance of Concentration Effects at the Electrode Surface in Anodic Stripping Voltammetric Measurements of Complexation of Metal Ions at Natural Water Concentrations

نویسنده

  • A. M. ALMEIDA
چکیده

The influence of the ligand/metal ion concentration ratio on the shape, peak current and peak potential of curves obtained by anodic stripping voltammetry (a.s.v.) at the hanging mercury drop electrode is described, particularly with respect to the use of a.s.v. for speciation of metal ions at very low concentrations as is often found in natural waters. The lead(II)/triethylenetetramine system is used as a model of a fully labile reversible system. It is shown that the total metal ion concentration at the electrode surface (&) during the stripping step may be much larger (30-300 times in typical conditions) than that in the bulk solution (CM), the exact value depending on the deposition time td. Consequently, changes in the peak characteristics are observed when the ligand/metal concentration ratio in the bulk of the solution, CL/CM, is less than 1000. Semi-empirical equations, experimentally tested, are given, which enable (&/CM to be estimated for a specified soluti& and a.s.v. conditions, which correct for the “surface concentration effect” when a.s.v. is used to measure complexation, and which describe the influence of the parameters such as stirring efficiency, radius of the mercury drop and CL/CM. The implications of the results are discussed for determinations of total metal ion in complex media, of speciation based on peak-potential shifts or stripping voltammetric curves, and of complexation capacity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Adsorptive Stripping Differential Pulse Voltammetric Measurements of Trace Lead, Cadmium and Nickel in the Presence of 2-aminobenzoic Acid

In this study, 2-aminobenzoic acid (ABA) has been used as complexing ligand for simultaneousdetermination of metal ions by adsorptive cathodic stripping voltammetry (AdCSV), for the firsttime. Thus, a selective and sensitive procedure was presented for simultaneous determination oflead, cadmium and nickel using ABA and differential pulse-adsorptive cathodic strippingvolt...

متن کامل

Construction of a Carbon Paste Electrode Based on Novel Thiolated Ligand Capped Gold Nanoparticles for Determination of Trace Amounts of Mercury(II)

In the present study, a simple electrochemical sensor for trace determination of Hg(II) ions in aqueous solutions was introduced. The proposed sensor was designed by incorporation of the 4-methyl-piperidine-carbodithioate capped gold nanoparticles (GNPs) into the carbon paste electrode (CPE), which provides a remarkably improved sensitivity for stripping voltammetric determination of Hg(II). Di...

متن کامل

Ultra-Sensitive Anodic Stripping Voltammetry for the Determination of Xanthine at a Glassy Carbon Electrode

An electrochemical anodic stripping procedure for ultra-trace assay of xanthine in Cu2þ solution at a glassy carbon electrode (GCE) is described. Cyclic voltammetry was used to characterize the nature of the process taking place at the GCE. The anodic stripping response in the presence of Cu2þ, at 150 mV (peak I) and 600 mV (peak II), is evaluated with respect to various experimental and instru...

متن کامل

Trace determination of cadmium in water using anodic stripping voltammetry at a carbon paste electrode modified with coconut shell powder

Background: Increasing awareness on the environmental impact of heavy metals has increased a considerable interest in the determination of metals in natural water bodies. The present paper describes the development and electrochemical application of carbon paste electrode modified with fibrous part of coconut shell for the determination of cadmium in water samples. Methods: Determination was ca...

متن کامل

An Electrochemical Sensor Based on Novel Ion Imprinted Polymeric Nanoparticles for Selective Detection of Lead Ions

In this study, the novel surface ion-imprinted polymer (IIP) particles were prepared and applied as a electrode modifier in stripping voltammetric detection of lead(II) ion. A carbon paste electrode (CPE) modified with IIP nanoparticles and multi-walled carbon nanotubes (MWCNTs) was used for accumulation of toxic lead ions. Various factors that govern on electrochemical signals including carbon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000