BrachyView: proof-of-principle of a novel in-body gamma camera for low dose-rate prostate brachytherapy.

نویسندگان

  • M Petasecca
  • K J Loo
  • M Safavi-Naeini
  • Z Han
  • P E Metcalfe
  • S Meikle
  • S Pospisil
  • J Jakubek
  • J A Bucci
  • M Zaider
  • M L F Lerch
  • Y Qi
  • A B Rosenfeld
چکیده

PURPOSE The conformity of the achieved dose distribution to the treatment plan strongly correlates with the accuracy of seed implantation in a prostate brachytherapy treatment procedure. Incorrect seed placement leads to both short and long term complications, including urethral and rectal toxicity. The authors present BrachyView, a novel concept of a fast intraoperative treatment planning system, to provide real-time seed placement information based on in-body gamma camera data. BrachyView combines the high spatial resolution of a pixellated silicon detector (Medipix2) with the volumetric information acquired by a transrectal ultrasound (TRUS). The two systems will be embedded in the same probe so as to provide anatomically correct seed positions for intraoperative planning and postimplant dosimetry. Dosimetric calculations are based on the TG-43 method using the real position of the seeds. The purpose of this paper is to demonstrate the feasibility of BrachyView using the Medipix2 pixel detector and a pinhole collimator to reconstruct the real-time 3D position of low dose-rate brachytherapy seeds in a phantom. METHODS BrachyView incorporates three Medipix2 detectors coupled to a multipinhole collimator. Three-dimensionally triangulated seed positions from multiple planar images are used to determine the seed placement in a PMMA prostate phantom in real time. MATLAB codes were used to test the reconstruction method and to optimize the device geometry. RESULTS The results presented in this paper show a 3D position reconstruction accuracy of the seed in the range of 0.5-3 mm for a 10-60 mm seed-to-detector distance interval (Z direction), respectively. The BrachyView system also demonstrates a spatial resolution of 0.25 mm in the XY plane for sources at 10 mm distance from Medipix2 detector plane, comparable to the theoretical value calculated for an equivalent gamma camera arrangement. The authors successfully demonstrated the capability of BrachyView for real-time imaging (using a 3 s data acquisition time) of different brachytherapy seed configurations (with an activity of 0.05 U) throughout a 60 × 60 × 60 mm(3) Perspex prostate phantom. CONCLUSIONS The newly developed miniature gamma camera component of BrachyView, with its high spatial resolution and real time capability, allows accurate 3D localization of seeds in a prostate phantom. Combination of the gamma camera with TRUS in a single probe will complete the BrachyView system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

شبیه سازی براکی تراپی رگ کرونر با استنت پرتوزای Re188 و محاسبه دز جذب شده در اندام های حیاتی نزدیک استنت

Intravascular brachytherapy is simulated with Palmaz-Schatz stent, manufactured by Cordis Co. that is radioactived with 188Re source, using the MCNPX code. Functions and dosimetric parameters, were calculated in  cylindrical coordinates and results compared with the latest standards and AAPM TG-60 group offers, published experimental data and also other performed simulations with various p...

متن کامل

Proof of Symmetric Dose Distribution in Mammosite Applicator in Breast Brachytherapy with MCNP Simulation

Introduction: In brachytherapy treatments, high-dose sources are used in interstitial placement. In this paper, the modeling of a common breast cancer treatment applicator called MammoSite is done by the Monte Carlo simulation code. Then, to study and calculate the amount of doses in the breast and the dose rate of the organs at risk of radiation, including: lungs, ribs and ski...

متن کامل

BrachyView, a novel inbody imaging system for HDR prostate brachytherapy: design and Monte Carlo feasibility study.

PURPOSE High dose rate (HDR) brachytherapy is a form of radiation therapy for treating prostate cancer whereby a high activity radiation source is moved between predefined positions inside applicators inserted within the treatment volume. Accurate positioning of the source is essential in delivering the desired dose to the target area while avoiding radiation injury to the surrounding tissue. I...

متن کامل

Determination of Dosimetric Characteristics of IrSeed 125I Brachytherapy Source

Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...

متن کامل

Historical review of interstitial prostate brachytherapy

In the recent years, interstitial brachytherapy implantation has become the treatment of choice for early stage prostate cancer patients. Treatment of prostate cancer with radiation is traced back to 1909. Originally this treatment modality was very crude and could not gain much popularity till 1982. Advancements in radioactive source designs, introduction of new low energy radioactive sources,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 40 4  شماره 

صفحات  -

تاریخ انتشار 2013