Evaluation of a posture tracking system

نویسندگان

  • MS Wong
  • WY Wong
چکیده

Background Spinal deviations usually refer to abnormal lateral or sagittal curvature that could be the cause or effect of some spinal diseases. The conventional orthotic intervention is to apply passive forces to a patient's body with an orthosis for supporting and controlling the trunk alignments. However, once the orthosis is removed, such functions cannot be maintained. Therefore, an active posture training approach is proposed for suitable clinical cases, as it can keep the trunk in appropriate posture using the patient's own back muscles, and a long-lasting effect is anticipated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Real-Time Sitting Posture Tracking System

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . INTRODUCTION 1 . . . . . . . . . . . . . . . . . . . . . . . . 1.1 Related Work in Computer Vision 2 1.1.1 Appearanced-Based Methods for Object Recognition . . . . . . . . . 3 1.1.2 Human Modeling and Tracking 'I 1 . . . . . . . . . . . . . ....

متن کامل

Design and Evaluation of a Pressure and Temperature Monitoring System for Pressure Ulcer Prevention

Introduction Pressure ulcers are tissue damages resulting from blood flow restriction, which occurs when the tissue is exposed to high pressure for a long period of time. These painful sores are common in patients and elderly, who spend extended periods of time in bed or wheelchair. In this study, a continuous pressure and temperature monitoring system was developed for pressure ulcer preventio...

متن کامل

Comparative Analysis of Posture Controllers for Tracking Control of a Four-Wheeled Skid-Steered Mobile Robot in Case of Non-Zero Initial Position and Course Errors

The paper is concerned with the problem of trajectory tracking control of a four-wheeled skid-steered mobile robot in case of non-zero initial position and course (posture) errors. Object of the research, its kinematics and dynamics were described. Structure of robot motion control system containing posture controller and drive controller is shown. Six solutions of the posture controller which ...

متن کامل

Development and validation of a novel rating system for scoring standing foot posture: the Foot Posture Index.

INTRODUCTION The limitations of clinical methods for appraising foot posture are well documented. A new measure, the Foot Posture Index is proposed, and its development and validation described. METHODS A four-phase development process was used: (i) to derive a series of candidate measures, (ii) to define an appropriate scoring system, (iii) to evaluate the validity of components and modify t...

متن کامل

Test and Evaluation of Patient Tracking Platform: Use of Near Field Communication

In an earthquake situation, medical response communities such as field and referral hospitals are being challenged with injured victims’ identification and tracking. In our project, we developed a patient tracking platform (PTP). In this platform, first responders triage the patients with an electronic tag that reports the location and some information of each patient during his or her movement...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2009