Robust Averaging Level Control
نویسندگان
چکیده
Frequent inlet flow changes typically cause problems for averaging level controllers. For a frequently changing inlet flow the upsets do not occur when the system is in steady state and the tank level at its set-point. For this reason the tuning of the level controller gets quite complicated, since not only the size of the upsets but also the time in between them relative to the hold up of the tank have to be considered. One way to obtain optimal flow filtering while directly accounting for future inlet flow upsets is to use closed-loop robust MPC, as proposed here. The behavior of the robust MPC controller differs from earlier proposed level controllers as it does not return the tank level to a fixed set-point following an inlet flow upset. Guidelines on the tuning of the controller is presented and its performance is compared to that of a previously proposed MPC approach.
منابع مشابه
Performance Analysis of Robust Averaging Level Control
Frequent inlet flow changes, especially in the same direction, typically cause problems for averaging level controllers. To obtain optimal flow filtering while being robust towards future inlet flow upsets closed loop robust MPC has been used. It differs from other averaging controllers in that it does not return the tank level to a fixed set-point, but rather lets it depend on the current inle...
متن کاملPerformance Analysis of Robust Averaging Level Control, Report no. LiTH-ISY-R-3030
Frequent inlet flow changes, especially in the same direction, typically cause problems for averaging level controllers. To obtain optimal flow filtering while being robust towards future inlet flow upsets closed loop robust MPC was used. Its performance and robustness is analyzed and compared to the optimal averaging level controller. The knowledge gained from the robust MPC exercise is also u...
متن کاملA robust aggregation operator for multi-criteria decision-making method with bipolar fuzzy soft environment
Molodtsov initiated soft set theory that provided a general mathematicalframework for handling with uncertainties in which we encounter the data by affix parameterized factor during the information analysis as differentiated to fuzzy as well as bipolar fuzzy set theory.The main object of this paper is to lay a foundation for providing a new application of bipolar fuzzy soft tool in ...
متن کاملAveraging level control in the presence of frequent inlet flow upsets
Buffer tanks are widely used within the process industry to prevent flow variations from being directly propagated throughout a plant. The capacity of the tank is used to smoothly transfer inlet flow upsets to the outlet. Ideally, the tank thus works as a low pass filter where the available tank capacity limits the achievable flow smoothing. For infrequently occurring upsets, where the system h...
متن کاملEuclidean Norm Robust Optimal Averaging Level Control, Report no. LiTH-ISY-R-3034
Using insights gained from the robust MPC design of (Rosander et al., 2011) an explicit robustly optimal controller is derived using the Euclidean norm as measure of flow smoothness. The derived controller gives a lower bound on the achievable filtering performance for any controller that mimic the behavior of the robust MPC controller.
متن کاملFactors Affecting Energy Intensity in Provinces of Iran: Bayesian Averaging Approach
The identification of the most important factors affecting energy intensity with the aim of controlling and managing energy consumption is an important topic. Findings of different empirical studies on the factors affecting energy intensity are inconsistent and this raises uncertainty about the employed models. One of the techniques that conform to these uncertainty conditions of the model is t...
متن کامل