Diagnostic accuracy of pocket-size handheld echocardiographs used by cardiologists in the acute care setting.

نویسندگان

  • Ariane Testuz
  • Hajo Müller
  • Pierre-Frédéric Keller
  • Philippe Meyer
  • Tomoe Stampfli
  • Lucka Sekoranja
  • Cédric Vuille
  • Haran Burri
چکیده

AIMS Pocket-size echographs may be useful for bedside diagnosis in acute cardiac care, but their diagnostic accuracy in this setting has not been well tested. Our aim was to evaluate this tool in patients requiring an urgent echocardiogram. METHODS Trained cardiologists performed echocardiograms with a pocket-size echograph (Vscan) in consecutive patients requiring urgent echocardiography. The exams were then compared in a blinded manner with echocardiograms performed with a high-end standard echocardiograph. RESULTS A total of 104 patients were studied. There was an excellent agreement between the Vscan and the high-end echocardiograph for the left ventricular systolic function and pericardial effusion (Kappa: 0.89 and 0.81, respectively), and the agreement was good or moderate for evaluating the aortic, mitral, and tricuspid valve function and the left ventricular size (Kappa: 0.55-0.66). Visualization of the Vscan images in full-screen format on a PC did not in general confer added value. CONCLUSION The Vscan used by a trained cardiologist has good diagnostic accuracy in the emergency setting compared with a high-end echocardiograph, despite small screen size and lack of pulse-wave and continuous Doppler.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Amniotic Fluid Index and Single Deepest Pocket Measurements in Predicting the Outcomes of Prolonged Pregnancies

Introduction: Two techniques for sonographic evaluation of amniotic fluid are Amniotic Fluid Index (AFI) and Single Deepest Pocket (SDP).  In this study,we aimed to determine the accuracy of AFI and SDP in predicting prolonged pregnancy outcomes. Methods: In this prospective, double-blinded, cohort study, 362 women with more than 40 weeks of gestational age were evaluated. Both AFI and SDP meth...

متن کامل

Diagnostic Accuracy of Acute Appendicitis by Ultrasound in Hospital Emergency

Background Acute appendicitis is the most common medical condition requiring immediate abdominal surgery.Medical ultrasound is a non-intrusive, non-expensive and available diagnostic method. In this study, the accuracy of ultrasound in diagnosis of acute appendicitis in hospital emergency was evaluated. Materials and Methods This retrospective cohort study was performed at Ahvaz Imam Khomeini h...

متن کامل

Estimating the accuracy of optic nerve sheath diameter measurement using a pocket-sized, handheld ultrasound on a simulation model

BACKGROUND Ultrasound measurement of optic nerve sheath diameter (ONSD) appears to be a promising, rapid, non-invasive bedside tool for identification of elevated intra-cranial pressure. With improvements in ultrasound technology, machines are becoming smaller; however, it is unclear if these ultra-portable handheld units have the resolution to make these measurements precisely. In this study, ...

متن کامل

The use of pocket size imaging devices: a position statement by the European Association of Echocardiography.

Pocket-size imaging devices are a completely new type of echo machines which have recently reached the market. They are very cheap, smartphone-size hand-held echo machines with limited technical capabilities. The aim of this European Association of Echocardiography (EAE) position paper is to provide recommendations on the use of pocket-size imaging devices in the clinical arena by profiling the...

متن کامل

Diagnostic performance of multi-organ ultrasound with pocket-sized device in the management of acute dyspnea

BACKGROUND The availability of ultra-miniaturized pocket ultrasound devices (PUD) adds diagnostic power to the clinical examination. Information on accuracy of ultrasound with handheld units in immediate differential diagnosis in emergency department (ED) is poor. The aim of this study is to test the usefulness and accuracy of lung ultrasound (LUS) alone or combined with ultrasound of the heart...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal cardiovascular Imaging

دوره 14 1  شماره 

صفحات  -

تاریخ انتشار 2013