Discontinuous and Continuous Indoor Air Quality Monitoring in Homes with Fireplaces or Wood Stoves as Heating System.

نویسندگان

  • Gianluigi de Gennaro
  • Paolo Rosario Dambruoso
  • Alessia Di Gilio
  • Valerio Di Palma
  • Annalisa Marzocca
  • Maria Tutino
چکیده

Around 50% of the world's population, particularly in developing countries, uses biomass as one of the most common fuels. Biomass combustion releases a considerable amount of various incomplete combustion products, including particulate matter (PM) and polycyclic aromatic hydrocarbons (PAHs). The paper presents the results of Indoor Air Quality (IAQ) measurements in six houses equipped with wood burning stoves or fireplaces as heating systems. The houses were monitored for 48-h periods in order to collect PM10 samples and measure PAH concentrations. The average, the maximum and the lowest values of the 12-h PM10 concentration were 68.6 μg/m³, 350.7 μg/m³ and 16.8 μg/m³ respectively. The average benzo[a]pyrene 12-h concentration was 9.4 ng/m³, while the maximum and the minimum values were 24.0 ng/m³ and 1.5 ng/m³, respectively. Continuous monitoring of PM10, PAHs, Ultra Fine Particle (UFP) and Total Volatile Organic Compounds (TVOC) was performed in order to study the progress of pollution phenomena due to biomass burning, their trends and contributions to IAQ. The results show a great heterogeneity of impacts on IAQ in terms of magnitude and behavior of the considered pollutants' concentrations. This variability is determined by not only different combustion technologies or biomass quality, but overall by different ignition mode, feeding and flame management, which can also be different for the same house. Moreover, room dimensions and ventilation were significant factors for pollution dispersion. The increase of PM10, UFP and PAH concentrations, during lighting, was always detected and relevant. Continuous monitoring allowed singling out contributions of other domestic sources of considered pollutants such as cooking and cigarettes. Cooking contribution produced an impact on IAQ in same cases higher than that of the biomass heating system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimating the Number of Vulnerable People in the United States Exposed to Residential Wood Smoke: Rogalsky et al. Respond

Estimating the Number of Vulnerable People in the United States Exposed to Residential Wood Smoke http://dx.doi.org/10.1289/ehp.1409136 Rogalsky et al. (2014) recently estimated the number of homes and individuals at risk of adverse health effects from exposure to emissions from residential wood combustion in the United States. We appreciate the importance of this topic, particularly to rural a...

متن کامل

Estimating the Number of Vulnerable People in the United States Exposed to Residential Wood Smoke

Estimating the Number of Vulnerable People in the United States Exposed to Residential Wood Smoke http://dx.doi.org/10.1289/ehp.1409136 Rogalsky et al. (2014) recently estimated the number of homes and individuals at risk of adverse health effects from exposure to emissions from residential wood combustion in the United States. We appreciate the importance of this topic, particularly to rural a...

متن کامل

Wood stove effects on indoor air quality in Brazilian homes: carcinogens, suspended particulate matter, and nitrogen dioxide analysis.

The effects of wood burning stoves on indoor air quality was investigated in a rural community of southern Brazil, during the winter season of 1991. The concentrations of polycyclic aromatic hydrocarbons (PAHs), nitrogen dioxide (NO2) and suspended particulate matter (SPM) were assessed in houses with wood stoves and the results compared with levels found in houses with gas stoves. Strikingly h...

متن کامل

Smoke: Emissions and Noncancer Respiratory Effects

During the past twenty years, the use of wood has become popular as an alternative to conventional home heating fuels. Part of this movement has been due to uncertainty about the availability of fossil fuels. About ten percent of space heating in urbanized areas of the northern United States is from wood burning, with up to fifty percent in some .smaller, rural towns (42, 63, 75, 85). Wood is o...

متن کامل

Asthma randomized trial of indoor wood smoke (ARTIS): rationale and methods.

BACKGROUND Particulate matter (PM) exposures have been linked with poor respiratory health outcomes, especially among susceptible populations such as asthmatic children. Smoke from biomass combustion for residential home heating is an important source of PM in many rural or peri-urban areas in the United States. AIM To assess the efficacy of residential interventions that reduce indoor PM exp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of environmental research and public health

دوره 13 1  شماره 

صفحات  -

تاریخ انتشار 2015