Reference measurement procedure for total glycerides by isotope dilution GC-MS.

نویسندگان

  • Selvin H Edwards
  • Shelton L Stribling
  • Susan D Pyatt
  • Mary M Kimberly
چکیده

BACKGROUND The CDC's Lipid Standardization Program established the chromotropic acid (CA) reference measurement procedure (RMP) as the accuracy base for standardization and metrological traceability for triglyceride testing. The CA RMP has several disadvantages, including lack of ruggedness. It uses obsolete instrumentation and hazardous reagents. To overcome these problems the CDC developed an isotope dilution GC-MS (ID-GC-MS) RMP for total glycerides in serum. METHODS We diluted serum samples with Tris-HCl buffer solution and spiked 200-μL aliquots with [(13)C(3)]-glycerol. These samples were incubated and hydrolyzed under basic conditions. The samples were dried, derivatized with acetic anhydride and pyridine, extracted with ethyl acetate, and analyzed by ID-GC-MS. Linearity, imprecision, and accuracy were evaluated by analyzing calibrator solutions, 10 serum pools, and a standard reference material (SRM 1951b). RESULTS The calibration response was linear for the range of calibrator concentrations examined (0-1.24 mmol/L) with a slope and intercept of 0.717 (95% CI, 0.7123-0.7225) and 0.3122 (95% CI, 0.3096-0.3140), respectively. The limit of detection was 14.8 μmol/L. The mean %CV for the sample set (serum pools and SRM) was 1.2%. The mean %bias from NIST isotope dilution MS values for SRM 1951b was 0.7%. CONCLUSIONS This ID-GC-MS RMP has the specificity and ruggedness to accurately quantify total glycerides in the serum pools used in the CDC's Lipid Standardization Program and demonstrates sufficiently acceptable agreement with the NIST primary RMP for total glyceride measurement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a candidate reference measurement procedure for the analysis of cortisol in human serum samples by isotope dilution-gas chromatography-mass spectrometry.

A candidate reference measurement procedure involving isotope dilution coupled with gas chromatography-mass spectrometry (GC-MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(2), was added to a serum sample. After equilibration, solid-phase extractions (SPE) for sample preparation and derivatization with heptafluorobutyric anhydride (HFBA) we...

متن کامل

Isotope dilution gas chromatographic-mass spectrometric measurement of tricyclic antidepressant drugs. Utility of the 4-carbethoxyhexafluorobutyryl derivatives of secondary amines.

Stable isotope dilution gas chromatographic-mass spectrometric (GC-MS) measurement of tricyclic antidepressants (TCA) is a useful alternative to high-performance liquid chromatography (HPLC) methods when interfering substances prevent accurate quantitation by HPLC. For satisfactory GC-MS analysis, secondary amine TCA must be derivatized. Commonly employed trifluoroacetyl and heptafluorobutyryl ...

متن کامل

Determination of ultra-trace levels of priority PBDEs in water samples by isotope dilution GC(ECNI)MS using 81Br-labelled standards.

A gas chromatography electron capture negative ionization mass spectrometry (GC(ECNI)MS) procedure for the determination of priority polybrominated diphenyl ethers (PBDEs; congeners 28, 47, 99, 100, 153 and 154) in water samples at regulatory EU levels has been developed. The method is based on the use of (81)Br-labelled PBDEs for isotope dilution analysis and the measurement of (79)Br/(81)Br i...

متن کامل

A Comparison of GC-ICP-MS and HPLC-ICP-MS for the Analysis of Organotin Compounds Application

An inductively coupled plasma mass spectrometer (ICP-MS) was used as a detector for gas chromatography (GC) and high performance liquid chromatography (HPLC) analysis of organotin compounds. ICP-MS is a highly sensitive detector with detection limits in the pg ng range, as well as enabling calibration by isotope dilution mass spectrometry (IDMS). Calibrating using isotopically labeled organotin...

متن کامل

Measurement of Serum 17α-hydroxyprogesterone in Newborn Infants by Stable Isotope Dilution—Gas Chromatography/Mass Spectrometry

Immunochemical measurement of serum 17α-hydroxyprogesterone (17OHP), the most important parameter for diagnosis of classical 21-hydroxylase deficiency (21OHD) in newborn infants, is known to be inaccurate due to the cross-reactivity of antibodies with a large quantity of fetal adrenal steroids. The aims of this study were 1) to establish reference values for the serum 17OHP level in Japanese ne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 58 4  شماره 

صفحات  -

تاریخ انتشار 2012