Clinical evaluation of a screen pneumotachograph as an in-line filter.

نویسندگان

  • H Normand
  • F Normand
  • X Le Coutour
  • M-A Metges
  • A Mouadil
چکیده

The American Thoracic Society/European Respiratory Society Task Force underlined that the use of in-line filters during respiratory function tests "is an area of controversy". The aim of the present study was to measure the contamination occurring during forced expiration downstream from a screen pneumotachograph (SP) with and without an in-line filter (Pall PF30S). A total of 40 healthy subjects performed eight consecutive maximal expiratory manoeuvres into four sterile apparatuses (A1: no filter, no SP; A2: filter-only; A3: SP-only; A4: filter and SP) in random order. A blood agar plate was fixed downstream from the apparatus. Colony-forming units (CFUs) were counted after 24 h incubation at 37 degrees C. Of the 40 plates obtained with each apparatus, 13 were sterile with A1 (range 0-679 CFUs), 25 with A2 (0-49 CFUs), 30 with A3 (0-35 CFUs) and 39 with A4 (one CFU in the only positive plate). A1 versus A2 and also A3 versus A4 gave different values for the CFU number, but A2 and A3 showed similar contamination levels. The authors conclude that: 1) the in-line filter does not perform better than a screen pneumotachograph; 2) it does not eliminate the need to decontaminate the pneumotachograph; and 3) equipment placed downstream from an in-line filter and a screen pneumotachograph is almost protected from contamination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Different Phenotypic and Genotypic Methods for Detection of Methicillin Resistant Staphylococcus aureus (MRSA)

Background: Methicillin resistant Staphylococcus aureus (MRSA) has been emerged as a nosocomial and community acquired pathogen worldwide. There are many challenges for laboratory detection of MRSA. The aim of this study was to compare different phenotypic methods with PCR based method as a gold standard for detection of mecA gene. <b...

متن کامل

Evaluation of Relationship between Smile Line and Age

Smile line is one of the most important element of the smile esthetics. In an attractive smile, the maxillary anterior incisal curve is parallel to the lower lip. With the changes in face, lips and teeth muscles, which are caused by aging, this element (smile line) also changes. Aging causes smile line to move from its parallel position and in complete smile, formulate different shapes relative...

متن کامل

Exploring Language Learners’ Cognitive Processes in On-line ESP Courses via Think-aloud Protocol Analysis

The present study aims to investigate language learners’ cognitive processes in on-line ESP courses. Three modes of inquiry are used: think-aloud protocol analysis, screen capture analysis, and correlation analysis. The theoretical foundations for the evaluation of the cognitive aspect of Ferdowsi Univeristy of Mashhad E-learning System are drawn from cognitive load theory, cognitive apprentice...

متن کامل

تقویت محور مرکزی ساختارهای لوله‌ای و کاربرد آن در استخراج محور مرکزی سیاهرگ پورتال

I In this paper, a new filter is designed to enhance medial-axis of tubular structures. Based on a multi-scale method and using eigenvectors of Hessian matrix, the distance of a point to the edges of the tube is found. To do this, a hypothetical line with a deliberate direction is passed through the point which cuts the tube at its edges. For points which are located on the medial-axis, this di...

متن کامل

Design and Implementation of a Kalman Filter-Based Time-Varying Harmonics Analyzer

Nowadays with increasing use of numerous nonlinear loads, voltage and current harmonics in power systems are one of the most important problems power engineers encounter. Many of these nonlinear loads, because of their dynamic natures, inject time-varying harmonics into power system. Common techniques applied for harmonics measurement and assessment such as FFT have significant errors in presen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 2007