Proposal of reference levels for cardiac interventional procedures. An European Coordination Action
نویسندگان
چکیده
Interventional cardiology is a medical specialty widely known to deliver high radiation dose to patients, who may receive, in some complex cases, skin doses over the threshold for deterministic effects. Because several studies have demonstrated large variability in delivered doses, European SENTINEL consortium has carried out a patient dose survey to propose regional Reference Levels (RL) as a tool to reduce dose variability and aid in the optimisation of radiation protection. The survey, performed in cardiac centres from 9 European countries, investigated doses in selected cardiac procedures: coronary angiography (CA), percutaneous transluminal coronary angioplasty (PTCA) and electrophysiology, collecting data on near 2,000 procedures. All examined doses, air kerma area product (KAP) and cumulative dose (CD) at the Interventional Reference Point, or dose analogues, fluoroscopy time and number of acquired images, exhibit a large variability. The examinations have been pooled and RL assessed as the 75° percentile of distributions. Proposed European RL for kerma-area product (KAP) are: 45, 85 and 35 Gycm2, for fluoroscopy time: 6.5, 15.5 and 21 min, respectively for CA, PTCA and diagnostic electrophysiology procedures. Because equipment performance is one of the factors contributing to patient dose variability, RL for air kerma for fluoroscopy and image acquisition measured (in low dose modes) at the entrance of a 20 cm PMMA phantom, are also proposed: 13 Gy/min and 100 μGy/image respectively. The study confirms a large variability of patient doses across Europe and the need of a set of European RL as a tool for the optimisation of radiation protection for patients. The complexity of the procedures should be introduced in the future to refine RL in fluoroscopy guided procedures (SENTINEL EURATOM Research contract No. 012909).
منابع مشابه
Reference levels at European level for cardiac interventional procedures.
In interventional cardiology, a wide variation in patient dose for the same type of procedure has been recognised by different studies. Variation is almost due to procedure complexity, equipment performance, procedure protocol and operator skill. The SENTINEL consortium has performed a survey in nine european centres collecting information on near 2000 procedures, and a new set of reference lev...
متن کاملEvaluation of Maximum Patient Skin Dose Arising from Interventional Cardiology Using Thermoluminescence Dosimeter in Mashhad, Iran
Introduction The increasing practice of interventional fluoroscopy in diagnosis and treatment of cardiovascular disease has risen attention to improve radiation protection of patients and cardiologists in these relatively high dose techniques. Therefore, nowadays there is an emphasis on the measurement of radiation dose received by patients and cardiologists arising from the relevant procedures...
متن کاملAssessment of Maximum Entrance Skin Dose of Patients Undergoing Cardiac Interventional Procedures and Its Correlation with Other Dosimetric Parameters
Introduction: In recent years, the number of complex coronary angiography (CA) is increasing rapidly. These procedures have a significant contribution to medical exposure to the general population. Exposure of patients to high doses of x-rays could cause deterministic effects on the skin. Therefore, the assessment of radiation doses of patients is of great importance. ...
متن کاملAssessment of Patient Radiation Dose in Interventional Procedures at Shahid Madani Heart Center in Khorramabad, Iran
Introduction: Coronary angiography is the most common angiographic procedure for diagnosis and treatment of the heart diseases. Herein, we aimed to evaluate the entrance surface dose (ESD), dose area product (DAP), as well as cancer risk in interventional cardiology procedures. Materials and Methods: This study was conducted during July-December 2015 at Shahid Madani Heart Center in Khorramabad...
متن کاملEvaluation of Patients’ effective dose in nuclear medicine department of Isfahan in order to define a local reference level
Introduction: Nowadays, nuclear medicine (NM) imaging indications in medical practice is raising. A practical step to get closer to the optimization rule is collecting data about patients’ exposure and definition of guidance levels. The aim of this study was definition of local reference level in Isfahan city. Materials and Methods: Questionnaires were given...