Accuracy of distortion-product otoacoustic emissions-based ototoxicity monitoring using various primary frequency step-sizes.
نویسندگان
چکیده
OBJECTIVE A cisplatin ototoxicity monitoring protocol was recently proposed using distortion-product otoacoustic emissions (DPOAEs) measured in 1/48th octave steps over the highest obtainable quarter octave ( Dille et al, 2010 ). This protocol can take up to 40 minutes to complete in both ears among seriously ill patients in a potentially noisy test environment. The goal of the current study was to contrast the diagnostic accuracy of ototoxicity monitoring protocols based on changes in DPOAE levels at wider, more rapidly tested, primary frequency step sizes. DESIGN Measure DPOAE levels in 1/48th octave steps over the highest half-octave of obtainable DPOAEs prior to treatment and at each ototoxicity monitoring session during the course of treatment with cisplatin. STUDY SAMPLE Nineteen cancer patients being treated with cisplatin at the Portland Veterans Affairs Medical Center were observed over 56 monitoring appointments. Hearing thresholds in the sensitive region for ototoxicity (SRO) were measured concurrently with DPOAE levels. RESULTS DPOAE levels measured in 1/24th octave steps provided comparable accuracy, and half the testing time, to the 1/48th octave step protocol previously described. CONCLUSIONS DPOAE level shifts measured in 1/24th octave steps may provide a basis for rapid ototoxicity monitoring among adult cancer patients treated with cisplatin.
منابع مشابه
Ototoxicity risk assessment combining distortion product otoacoustic emissions with a cisplatin dose model.
An objective method for identifying ototoxic hearing loss among patients receiving cisplatin is necessary since the ability of patients to take a behavioral test may change over the course of treatment. Data from 56 monitoring visits by 19 Veterans taking cisplatin were used to identify combinations of distortion-product otoacoustic emission (DPOAE) metrics and ototoxicity risk factors that bes...
متن کاملDistortion-product otoacoustic emission test performance for ototoxicity monitoring.
INTRODUCTION A nonbehavioral method for monitoring ototoxicity in patients treated with cisplatin is needed because patients enduring chemotherapy may not be well or cooperative enough to undergo repeated hearing tests. Distortion-product otoacoustic emissions (DPOAEs) provide a nonbehavioral measure of auditory function that is sensitive to cisplatin exposure. However, interpreting DPOAE findi...
متن کاملFactors affecting sensitivity of distortion-product otoacoustic emissions to ototoxic hearing loss.
OBJECTIVES (1) To determine the ototoxicity detection rate (sensitivity) for distortion-product otoacoustic emissions (DPOAEs) testing in adults who received ototoxic medications and experienced pure-tone threshold changes during the course of treatment; (2) to determine the extent to which DPOAE sensitivity to ototoxicity depends on the type of drug administered (platinum or antibiotic), magni...
متن کاملComparison of the Effectiveness of Monitoring Cisplatin-Induced Ototoxicity with Extended High-Frequency Pure-Tone Audiometry or Distortion-Product Otoacoustic Emission
BACKGROUND AND OBJECTIVES To compare the effectiveness of monitoring cisplatin-induced ototoxicity in adult patients using extended high-frequency pure-tone audiometry (EHF-PTA) or distortion-product otoacoustic emission (DP-OAE) and to evaluate the concurrence of ototoxicity and nephrotoxicity in cisplatin-treated patients. SUBJECTS AND METHODS EHF-PTA was measured at frequencies of 0.25, 0....
متن کاملDistortion-product otoacoustic emissions and auditory brainstem responses sensitivity assessment in cisplatin-induced ototoxicity in rats.
UNLABELLED Cisplatin (cis-diamminedicloroplatinum) is an antineoplastic drug used in the treatment of a variety of cancers, especially head-and-neck cancer. Its ototoxicity, however, has been noted as a common side-effect which limits its use and causes significant morbidity. AIM to assess distortion-product otoacoustic emissions (DPOAE) and brainstem evoked response audiometry (BERA) sensiti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of audiology
دوره 51 9 شماره
صفحات -
تاریخ انتشار 2012