Multi-Channeled Polymeric Microsystem for Studying the Impact of Surface Topography on Cell Adhesion and Motility

نویسندگان

  • Andres Diaz Lantada
  • Hernán Alarcón Iniesta
  • Esmaiel Jabbari
  • Jianxun Ding
چکیده

This paper presents the complete development and experimental validation of a microsystem designed to systematically assess the impact of surface topography on cell adhesion and dynamics. The microsystem includes two pools for culturing cells and for including chemicals. These pools are connected by several channels that have different microtextures, along which the cells crawl from one well to another. The impact of channel surface topography on cell performance, as well as the influence of other relevant factors, can therefore be assessed. The microsystem stands out for its being able to precisely define the surface topographies from the design stage and also has the advantage of including the different textures under study in a single device. Validation has been carried out by culturing human mesenchymal stem cells (hMSCs) on the microsystem pre-treated with a coating of hMSC conditioned medium (CM) produced by these cells. The impact of surface topography on cell adhesion, motility, and velocity has been quantified, and the relevance of using a coating of hMSC-CM for these kinds of studies has been analyzed. Main results, current challenges, and future proposals based on the use of the proposed microsystem as an experimental resource for studying cell mechanobiology are also presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of novel anodized titanium for enhanced recruitment of H9C2 cardiac myoblast

Objective(s):Anodized treated titanium surfaces, have been proposed as potential surfaces with better cell attachment capacities. We have investigated the adhesion and proliferation properties of H9C2 cardiac myoblasts on anodized treated titanium surface.  Materials and Methods: Surface topography and anodized tubules were examined by high-resolution scanning electron microscopy (SEM). Contro...

متن کامل

The Study of Collagen Immobilization on a Novel Nanocomposite to Enhance Cell Adhesion and Growth

Background: Surface properties of a biomaterial could be critical in determining biomaterial’s biocompatibility due to the fact that the first interactions between the biological environment and artificial materials are most likely occurred at material’s surface. In this study, the surface properties of a new nanocomposite (NC) polymeric material were modified by combining plasma treatment and...

متن کامل

Isolation of Herpetosiphon giganteus and Ultrastructure Analysis by Electron Microscopy

Herpetosiphon giganteus is a filamentous gliding bacterium. Gliding motility is the movement of the cells over surfaces without the aid of flagella. The mechanism responsible for bacterial gliding motility has not been known and there are only a few data on Herpetosiphon giganteus. The aim of this study was to observe the ultrastructure and negative staining of isolated strains of Herpetosiphon...

متن کامل

Characterization of Nd: Yag Laser Radiation Effects on Ti6Al4V Physico-Chemical Properties: An In Vivo Study

The effect of a Nd: YAG laser (1064 nm) has been studied on Ti6Al4V alloy in terms of optical and physical parameters for biomedical applications. The superior surface microhardness hardness (i.e. 377 VHN) is attributed to grain refinement associated with laser melting and rapid solidification. The electrochemical property, mainly pitting corrosion resistance, has been carried out in Hanks salt...

متن کامل

Roughness Model for Adhesion Testing of Pharmaceutical Coating Materials

Objective Roughness is the main parameter in interlocking bonding mechanism. Yet there is no model designed to evaluate the effect of surface roughness on adhesion of coating materials in pharmaceutical sciences. Materials and Methods In this study polymethyl metacrylate spherical beads with different sizes were poured into 10 mm mold, then it was pressed by hand screw and finally heated to 141...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015