Mapping of transrectal ultrasonographic prostate biopsies: quality control and learning curve assessment by image processing

نویسندگان

  • Pierre Mozer
  • Michael Baumann
  • Grégoire Chevreau
  • Alexandre Moreau-Gaudry
  • Stéphane Bart
  • Raphaële Renard-Penna
  • Eva Comperat
  • Pierre Conort
  • Marc-Olivier Bitker
  • Emmanuel Chartier-Kastler
  • Francois Richard
  • Jocelyne Troccaz
چکیده

OBJECTIVE Mapping of transrectal ultrasonographic (TRUS) prostate biopsies is of fundamental importance for either diagnostic purposes or the management and treatment of prostate cancer, but the localization of the cores seems inaccurate. Our objective was to evaluate the capacities of an operator to plan transrectal prostate biopsies under 2-dimensional TRUS guidance using a registration algorithm to represent the localization of biopsies in a reference 3-dimensional ultrasonographic volume. METHODS Thirty-two patients underwent a series of 12 prostate biopsies under local anesthesia performed by 1 operator using a TRUS probe combined with specific third-party software to verify that the biopsies were indeed conducted within the planned targets. RESULTS The operator reached 71% of the planned targets with substantial variability that depended on their localization (100% success rate for targets in the middle and right parasagittal parts versus 53% for targets in the left lateral base). Feedback from this system after each series of biopsies enabled the operator to significantly improve his dexterity over the course of time (first 16 patients: median score, 7 of 10 and cumulated median biopsy length in targets of 90 mm; last 16 patients, median score, 9 of 10 and a cumulated median length of 121 mm; P = .046). CONCLUSIONS In addition to being a useful tool to improve the distribution of prostate biopsies, the potential of this system is above all the preparation of a detailed "map" of each patient showing biopsy zones without substantial changes in routine clinical practices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

18F-Choline PET/MRI: The Additional Value of PET for MRI-Guided Transrectal Prostate Biopsies.

UNLABELLED We assessed the value of fusion (18)F-fluoromethylcholine ((18)F-choline) PET/MRI for image-guided (targeted) prostate biopsies to detect significant prostate cancer (Gleason ≥ 3 + 4) compared with standard (systematic 12-core) biopsies. METHODS Within an ongoing prospective clinical trial, hybrid (18)F-choline PET/CT and multiparametric 3T MRI (mpMRI) of the pelvis were performed ...

متن کامل

Efficiency of short and long term antimicrobial therapy in transrectal ultrasound-guided prostate biopsies.

OBJECTIVE Prostate biopsy is a frequent diagnostic measure to detect prostatic conditions, including primarily prostate cancer. Its performance does not follow a pattern, mainly regarding preparation for the examination through antimicrobial prophylaxis. The aim of this study is to compare the efficiency of short and long term antimicrobial prophylaxis in transrectal ultrasound-guided prostate ...

متن کامل

Computerized analysis of transrectal ultrasonography images in the detection of prostate carcinoma.

OBJECTIVE To report on the use of automated image analysis in the interpretation of transrectal ultrasonographic images of the prostate. PATIENTS AND METHODS During transrectal ultrasonography, images were recorded from biopsies performed in 127 patients. Subsequently in the image, the puncture place was marked and analysed. Analysis of the images was performed with the Automated Urologic Dia...

متن کامل

Framework for 3D TransRectal Ultrasound

Introduction and Objective: Prostate biopsies are mainly performed under 2D TransRectal UltraSound (TRUS) control by sampling the prostate according to a predefined pattern. In case of first biopsies, this pattern follows a random systematic plan. Sometimes, repeat biopsies can be needed to target regions unsampled by previous biopsies or resample critical regions (for example in case of cancer...

متن کامل

Magnetic Resonance Image-Guided Biopsies with a High Detection Rate of Prostate Cancer

AIM To explore the potential of transrectal magnetic resonance image- (MRI-) guided biopsies of the prostate in a patient cohort with prior negative ultrasound guided biopsies. PATIENTS AND METHODS Ninety-six men with suspected prostate cancer underwent MRI-guided prostate biopsies under real-time imaging control in supine position. RESULTS Adenocarcinoma of the prostate was detected in 39 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine

دوره 28 4  شماره 

صفحات  -

تاریخ انتشار 2009