Measurement of Serum 17α-hydroxyprogesterone in Newborn Infants by Stable Isotope Dilution—Gas Chromatography/Mass Spectrometry
نویسندگان
چکیده
Immunochemical measurement of serum 17α-hydroxyprogesterone (17OHP), the most important parameter for diagnosis of classical 21-hydroxylase deficiency (21OHD) in newborn infants, is known to be inaccurate due to the cross-reactivity of antibodies with a large quantity of fetal adrenal steroids. The aims of this study were 1) to establish reference values for the serum 17OHP level in Japanese newborn infants using non-immunochemical stable isotope dilution -gas chromatography/mass spectrometry (SID-GC/MS) and 2) to compare the serum 17OHP levels determined by SID-GC/MS with those determined by radioimmunoassay (RIA). The first study subjects were used for determination of reference values and included 57 healthy full-term newborn infants (4-5 d of age). The second study subjects were used for comparison of SID-GC/MS with RIA and included 27 healthy full-term newborn infants (3-6 d of age) and two subjects with neonatal transient hyper 17OHPnemia; these two subjects were 16 and 27 d of age, respectively. In the first study subjects, the intra-assay coefficient of variation for SID-GC/MS was 3% (n=5), the recovery rate was 98%, the sensitivity was 0.2 ng/ml, and the range of linearity was 0.5-200 ng/ml. The reference values for the serum 17OHP level determined by SID-GC/MS ranged from 0.3-1.5 (0.6) (ng/ml) (median). In the second study subjects, the serum 17OHP levels determined by SID-GC/MS were lower in one of the 27 subjects and both of the two subjects with neonatal transient hyper 17OHPnemia compared with the levels determined by RIA. Measurement of the serum 17OHP level using SID-GC/MS may be clinically useful for definitive diagnosis of classical 21OHD in newborn infants.
منابع مشابه
Stable-isotope dilution gas chromatography-mass spectrometric measurement of 3-hydroxyglutaric acid, glutaric acid and related
We developed a simple and sensitive stable-isotope dilution method for the quantification of 3-hydroxyglutaric acid (3HGA) and glutaric acid (GA) in body fluids. In our method, tertbutyldimethylsilyl derivatives of 3HGA and GA were measured with a conventional electron-impact ionization mode in gas chromatography-mass spectrometry. The control values for 3HGA in nmol/ml were 0.15 ± 0.08 (serum;...
متن کاملWhen do gut flora in the newborn produce 3-phenylpropionic acid? Implications for early diagnosis of medium-chain acyl-CoA dehydrogenase deficiency.
Urinary excretion of 3-phenylpropionylglycine (PPG) is a diagnostic marker for medium-chain acyl-CoA dehydrogenase (MCAD) deficiency. PPG is derived from 3-phenylpropionic acid (PPA), a product of anaerobic bacterial metabolism in the gut. To determine when the infant gut was colonized with PPA-producing bacteria, we cultured stool in prereduced thioglycollate broth from 93 apparently healthy i...
متن کاملMeasurement of blood volume with an enriched stable isotope of chromium (53Cr) and isotope dilution by combined gas chromatography-mass spectrometry.
We used an established isotope dilution gas chromatography-mass spectrometry method to measure blood volumes with an enriched stable isotope of chromium. The results were compared with those of the conventional method, which involves radioactive 51Cr. The two methods were compared simultaneously in two male subjects of different sizes, and essentially identical volumes were obtained. The isotop...
متن کاملMeasurement of urea in human serum by isotope dilution mass spectrometry: a reference procedure.
BACKGROUND A reference measurement procedure is needed to demonstrate the traceability of results of urea measurements in human serum. We developed a measurement procedure using the principle of isotope dilution gas chromatography/mass spectrometry. METHODS [(13)C,(15)N(2)]Urea as internal standard was added to a serum sample and equilibrated with endogenous nonlabeled urea. For the preparati...
متن کاملTotal cholesterol in serum determined by isotope dilution/mass spectrometry, with liquid-chromatographic separation.
We describe an accurate, precise method for determination of total serum cholesterol by isotope dilution/mass spectrometry (IDMS) with liquid-chromatographic separation. After adding [3,4-13C]cholesterol to serum and hydrolyzing the cholesterol esters, we extract the total cholesterol. "High-performance" liquid chromatography (HPLC) is used to separate the extracted cholesterol for measurement ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 18 شماره
صفحات -
تاریخ انتشار 2009