High-resolution microPET imaging of carcinoembryonic antigen-positive xenografts by using a copper-64-labeled engineered antibody fragment.
نویسندگان
چکیده
Rapid imaging by antitumor antibodies has been limited by the prolonged targeting kinetics and clearance of labeled whole antibodies. Genetically engineered fragments with rapid access and high retention in tumor tissue combined with rapid blood clearance are suitable for labeling with short-lived radionuclides, including positron-emitting isotopes for positron-emission tomography (PET). An engineered fragment was developed from the high-affinity anticarcinoembryonic antigen (CEA) monoclonal antibody T84.66. This single-chain variable fragment (Fv)-C(H)3, or minibody, was produced as a bivalent 80 kDa dimer. The macrocyclic chelating agent 1,4,7, 10-tetraazacyclododecane-N,N',N", N"'-tetraacetic acid (DOTA) was conjugated to the anti-CEA minibody for labeling with copper-64, a positron-emitting radionuclide (t(1/2) = 12.7 h). In vivo distribution was evaluated in athymic mice bearing paired LS174T human colon carcinoma (CEA positive) and C6 rat glioma (CEA negative) xenografts. Five hours after injection with (64)Cu-DOTA-minibody, microPET imaging showed high uptake in CEA-positive tumor (17.9% injected dose per gram +/- 3.79) compared with control tumor (6.0% injected dose per gram +/- 1.0). In addition, significant uptake was seen in liver, with low uptake in other tissues. Average target/background ratios relative to neighboring tissue were 3-4:1. Engineered antibody fragments labeled with positron-emitting isotopes such as copper-64 provide a new class of agents for PET imaging of tumors.
منابع مشابه
Targeting CEA in Pancreas Cancer Xenografts with a Mutated scFv-Fc Antibody Fragment
BACKGROUND Sensitive antibody-based tumor targeting has the potential not only to image metastatic and micrometastatic disease, but also to be the basis of targeted therapy. The vast majority of pancreas cancers express carcinoembryonic antigen (CEA). Thus, we sought to evaluate the potential of CEA as a pancreatic cancer target utilizing a rapidly clearing engineered anti-CEA scFv-Fc antibody ...
متن کاملOptimizing radiolabeled engineered anti-p185HER2 antibody fragments for in vivo imaging.
We have recently described the in vivo properties of an iodinated anti-p185HER2 engineered antibody fragment [minibody (scFv-C(H)3)2; 80 kDa], made from the internalizing 10H8 monoclonal antibody. Although the 10H8 minibody showed excellent binding to the target in vitro, only modest tumor uptake [5.6 +/- 1.7% injected dose per gram (ID/g) of tissue] was achieved in nude mice bearing MCF7/HER2 ...
متن کاملPET imaging of CXCR4 using copper-64 labeled peptide antagonist
Expression of CXCR4 in cancer has been found to correlate with poor prognosis and resistance to chemotherapy. In this study we developed a derivative of the CXCR4 peptide antagonist, T140-2D, that can be labeled easily with the PET isotope copper-64, and thereby enable in vivo visualization of CXCR4 in tumors. T140 was conjugated to 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid mono ...
متن کاملHumanized radioiodinated minibody for imaging of prostate stem cell antigen-expressing tumors.
PURPOSE Prostate stem cell antigen (PSCA) is a cell surface glycoprotein that is overexpressed in prostate cancer, including hormone refractory disease. Previous preclinical studies showed the intact anti-PSCA antibodies, 1G8 and hu1G8, localized specifically to PSCA-expressing xenografts. Optimal micro positron emission tomography (microPET) imaging using hu1G8, however, required a delay of 16...
متن کاملMinibody: A novel engineered anti-carcinoembryonic antigen antibody fragment (single-chain Fv-CH3) which exhibits rapid, high-level targeting of xenografts.
A novel engineered antibody fragment (VL-VH-CH3, or "minibody") with bivalent binding to carcinoembryonic antigen (CEA) was produced by genetic fusion of a T84.66 (anti-CEA) single-chain antibody (scFv) to the human IgG1 CH3 domain. Two designs for the connecting peptide were evaluated. In the T84.66/212 LD minibody, a two-amino acid linker (generated by fusion of restriction sites) was used to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Proceedings of the National Academy of Sciences of the United States of America
دوره 97 15 شماره
صفحات -
تاریخ انتشار 2000