Cochlea size variability and implications in clinical practice

نویسندگان

  • P. PELLICCIA
  • F. VENAIL
  • A. BONAFÉ
  • M. MAKEIEFF
  • G. IANNETTI
  • M. BARTOLOMEO
  • M. MONDAIN
چکیده

THE OBJECTIVES OF THIS STUDY WERE 1) study cochlea size variability among age and degree of deafness; 2) calculate the length of the cochlear implant electrode needed to obtain the optimal final insertion depth angle of 270°. A total of 241 patients (482 ears) that underwent high resolution computed tomography (HRCT) of the ear in our Institution between 2003 and 2008 were included to collect temporal bone data, and were divided in 3 groups: 97 (194 ears) patients with bilateral severe or profound sensorineural hearing loss (Group A), 70 patients (140 ears) with bilateral moderate sensorineural hearing loss (Group B), 74 patients (148 ears) without sensorineural or mixed hearing loss (Group C). In each of the 3 groups, 5 subgroups were identified with the following age criteria: 1) subgroup 1: subjects ≤5 years old; 2) subgroup 2: subjects 6-10 years old; 3) subgroup 3: patients 11-15 years old; 4) subgroup 4: patients 16-20 years old; 5) subgroup 5: subjects >; 20 years old. The length of the cochlea, height of the cochlea, basal turn lumen diameter (BTLD) and volume of the cochlea were measured. The Mann-Whitney test was used to assess the alternative hypothesis that a statistically significant difference in size exists between the different groups and subgroups. The following equation was adopted to calculate the length of a straight electrode which follows the outer wall of the scala tympani required to obtain the ideal insertion depth angle of 270°( LIC ): [Formula: see text] . We found that the cochlea is completely developed and has reached adult size at birth. The degree of deafness does not affect the length or volume of the cochlea, while it can affect the height and BTLD. To assist the surgeon to calculate the ideal insertion depth angle of 270° in order to preserve residual hearing, it is useful to propose a straight electrode with 3 landmarks on the array (the first at 16.635 mm from the tip, the second at 17.987 mm and the third at 19.34 mm).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variations in microanatomy of the human cochlea

The human cochlea shows considerable interindividual variability in size and morphology. In order to develop atraumatic cochlear implant (CI) electrodes, high-precision details of the variability of human anatomy are required. Sixteen human temporal bones were cut around the cochlea in blocks of approximately 3.5 × 3.5 cm. The bones were scanned by using a Skyscan 1173 micro-computed tomography...

متن کامل

Future-oriented implications of the resilience theory for Iran public libraries

Target: In order to play their role in social developments, public libraries face technological changes and unknown issues that can affect their identity and mission .In reference to the application of novel approaches to reconceptualize the mission of public libraries, this study tries to employ resilience theory to craft a vision for the future of Iran public libraries. Method: This study u...

متن کامل

System Factors Influencing the Australian Nurses' Evidence-based Clinical Decision Making: A Systematic Review of Recent Studies

Background: There is growing attention to evidence-based practice in Australian clinical contexts and nursing literature. Recent research explores the dimensions of evidence-based practice; however, the implementation of evidence-based clinical decision making has been identified as a cumbersome process. Aim: This study aimed to review the literature syst...

متن کامل

Clinical Implications of Congenital Absence of Circumflex Coronary Artery

Introduction: Coronary artery anomalies are rare clinical entities reported in 0.6% to 5.6% of diagnostic coronary angiographies. Anomalous origins of coronary arteries from distal segments are rarely reported. Presented herein is a coronary anomaly in which the circumflex artery (CX) originated as a continuation of the posterolateral branch of the right coronary artery (RCA) w...

متن کامل

Effect of variability of combined practice (physical and positive self-modeling) on memory reconsolidation and motor skill transfer in children

In this study we manipulate structure of combined practice (physical along with self-modeling of positive self-review) to examine its effects on motor memory reconsolidation process and motor transfer in children. 36 female students (9-12 years old) from Maktabi elementary school of Qom trained Dart throwing. Of the 15 trials (from 1.5, 2, and 2.5 meters in blocked order), Positive self-re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 34  شماره 

صفحات  -

تاریخ انتشار 2014