Reliability, Validity, and Diagnostic Value of a Pediatric Bioelectrical Impedance Analysis Scale.

نویسندگان

  • Laura S Kabiri
  • Daphne C Hernandez
  • Katy Mitchell
چکیده

BACKGROUND Accurate body composition assessment is critical to identify children who are overfat or obese. Unlike BMI measures, bioelectrical impedance analysis (BIA) differentiates between lean and fat mass. However, bioelectrical impedance analysis has historically had questionable reliability and validity in children. The aim of this study was to determine the reliability, validity, and diagnostic value of a portable BIA scale (Tanita BF-689; Tanita Corporation, Tokyo, Japan) designed specifically for use within the pediatric population. METHODS Fifty-five children (males = 26; females = 29) had percent body fat (%BF) assessed twice using BIA and once using dual-energy X-ray absorptiometry (DEXA). Intraclass correlation coefficients (ICCs) were calculated for reliability. Mean difference and limits of agreement were calculated for convergent validity. Sensitivity/specificity for healthy, overfat, and obese classification were assessed. RESULTS Test-retest ICC was 0.999 (0.999, 0.999). The ICC comparing BIA and DEXA for %BF was 0.788 (-0.167, 0.942). Mean difference between BIA and DEXA was -6.75% (limits of agreement = -0.04%; -13.46%). No gender or proportional bias was observed. Sensitivity/specificity for healthy, overfat, and obese classification were 0.67/0.65, 0.22/0.78, and 0.43/1.0, respectively. CONCLUSIONS The Tanita BF-689 demonstrates excellent test-retest reliability, moderately strong absolute agreement with DEXA, and high specificity for overfat and obese classification. Compared to DEXA, the BF-689 is an accurate, portable, and efficient means of assessing %BF in elementary school children.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis

Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...

متن کامل

Validity and reliability of bioelectrical impedance analysis and skinfold thickness in predicting body fat in military personnel.

Previous studies show that body composition is related to injury risk and physical performance in soldiers. Thus, valid methods for measuring body composition in military personnel are needed. The frequently used body mass index method is not a valid measure of body composition in soldiers, but reliability and validity of alternative field methods are less investigated in military personnel. Th...

متن کامل

Bioelectrical Impedance versus Body Mass Index for Predicting Body Composition Parameters in Sedentary Job Women

Objective: Nowadays the value of bioelectrical impedance analysis (BIA) in the estimation of body adiposity both on a clinical basis in the individual and epidemiologically in large populations is of great interest. The current study determine accuracy of BIA compared with body mass index (BMI) measurement for estimating body composition in a group of normal weight employee women with a sedenta...

متن کامل

Bioelectrical impedance analysis for assessment of severity of illness in pediatric patients after heart surgery.

OBJECTIVE To investigate whether perioperative changes in bioelectrical impedance reflect the severity of illness in pediatric patients after heart surgery. DESIGN Prospective, controlled study. SETTING University-affiliated children's hospital. PATIENTS A total of 107 patients admitted to a pediatric intensive care unit after congenital heart surgery. INTERVENTIONS None. MEASUREMENTS...

متن کامل

Volaemic assessment of the elderly hyponatraemic patient: reliability of clinical assessment and validation of bioelectrical impedance analysis.

BACKGROUND Hyponatraemia is the commonest electrolyte disturbance of hospital inpatients. Assessment of volaemic status is an important part of diagnosis and management. AIM To determine reliability of clinical assessment of volaemic state by assessing inter-observer variability of clinical measures of volaemic state. To assess validity of bioelectrical impedance analysis as a tool to measure...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Childhood obesity

دوره 11 5  شماره 

صفحات  -

تاریخ انتشار 2015