Optimizing detector geometry for trace element mapping by X-ray fluorescence.
نویسندگان
چکیده
Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples.
منابع مشابه
- iii - LBL - 647 TRACE ELEMENT ANALYSIS WITH SEMICONDUCTOR DETECTOR X - RAY SPECTROMETERS *
A method of obtaining high sensitivity and precision in x-ray fluorescence analysis using semiconductor detector spectrometers is discussed. Monoenergetic exciting radiation is employed to generate characteristic x-rays from trace elements in thin, uniform specimens. Corrections for absorption effects are determined; enhancement effects are omitted as they are negligible for many thin specimens...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملTotal Reflection X-ray Fluorescence Spectrometry for Characterization of Nuclear Materials
Total reflection X-Ray Fluorescence (TXRF) is a comparatively new technique of material characterization and trace element analysis. It is an advanced variant of Energy Dispersive X-ray Fluorescence (EDXRF) and is based on the principle of total reflection of X-rays when these radiations fall on a flat smooth surface at a grazing angle less than the critical angle of the sample support. The cri...
متن کاملBiological applications of X-ray fluorescence microscopy: exploring the subcellular topography and speciation of transition metals.
Synchrotron X-ray fluorescence microscopy (SXRF) is a microanalytical technique for the quantitative mapping of elemental distributions. Among currently available imaging modalities, SXRF is the only technique that is compatible with fully hydrated biological samples such as whole cells or tissue sections, while simultaneously offering trace element sensitivity and submicron spatial resolution....
متن کاملCompact x-ray microtomography system for element mapping and absorption imaging.
We have designed and built a compact x-ray microtomography system to perform element mapping and absorption imaging by exploiting scanning fluorescence tomography and full-field transmission microtomography, respectively. It is based on a low power microfocus tube and is potentially appropriate for x-ray diagnostics in space. Full-field transmission tomography yields the three-dimensional inner...
متن کاملذخیره در منابع من