Direct comparison of steroid and non-steroid eluting small surface pacing leads: randomized, multicenter clinical trial.
نویسندگان
چکیده
BACKGROUND The aim of the study was to evaluate the efficacy and safety of small surface steroid-eluting atrial and ventricular pacing leads in comparison to non-steroid leads using remote monitoring system (Biotronik Home Monitoring®). METHODS In this randomized multicenter prospective trial, SIELLO T steroid-eluting ventricular leads (n = 42) were compared to BPPU T non-steroid leads (n = 46) and SIELLO JT steroid-eluting atrial leads (n = 24) to BPPU JT non-steroid leads (n = 27) (Biotronik, Berlin, Germany) in pacemaker devices with remote monitoring capabilities. Lead parameters were evaluated during implantation, at 1-week and 1, 3, 6-month outpatient follow-up. Remote monitoring data were collected weekly. RESULTS Atrial and ventricular steroid-eluting leads had stable sensing and impedance as compared to non-steroid leads at implantation and during follow-up. Patients with non-steroid atrial leads had significantly higher threshold compared to steroid leads at 1-week and at 1, 3, 6-month follow-up with a peak at 1-month (1-month 1.4 ± 0.6 vs. 0.7 ± 0.3 V at 0.4 ms, p < 0.001; 6-month 0.3 ± 0.5 vs. 0.2 ± 0.3 V at 0.4 ms, p = 0.002). Patients with non-steroid ventricular leads had significantly higher threshold compared to steroid leads at 1, 3, 6-month (6-month 1.0 ± 0.3 vs. 0.6 ± 0.2 V at 0.4 ms, p < 0.001). Remote monitoring confirmed consistent results. During the study, 3 patients died of non-lead-related death. Lead repositioning was necessary in 2 atrial, 2 ventricular steroid leads and in 1 ventricular non-steroid lead. CONCLUSIONS Atrial and ventricular pacemaker leads with steroid showed significantly lower pacing threshold compared to non-steroid leads, confirmed by remote monitoring.
منابع مشابه
Acute performance of steroid-eluting screw-in leads for atrial free wall pacing.
The aim of this study was to clarify the acute performance of steroid-eluting screw-in leads in comparison with that of nonsteroid screw-in leads for atrial free wall pacing. In 114 cases (68 males, 46 females, average age 70 years) with atrial free wall pacing by screw-in leads, pacing thresholds and P-wave amplitudes were compared at the time of implantation and 1 week later between 68 cases ...
متن کاملEpicardial pacing wires, a five year, single centre experience
Results On implantation the mean threshold of all the leads was 1.1+/-0.8V at a mean pulse width of 0.5+/-0.7ms. The mean impedance of the leads was 673.4+/-268.1 OH. There was no difference in the implant data between unipolar and bipolar or steroid eluting and non-steroid eluting leads. There was a significantly lower pacing threshold in the steroid eluting leads at latest follow up (p=0.031)...
متن کاملEpicardial left ventricular leads via minimally invasive technique: a role of steroid eluting leads
BACKGROUND We retrospectively assessed two types of sutureless screw-in left ventricular (LV) leads (steroid eluting vs. non-steroid eluting) in cardiac resynchronization therapy (CRT) implantation with regards to their electrical performance. METHODS Between March 2008 and May 2014 an epicardial LV lead was implanted in 32 patients after failed transvenous LV lead placement using a left-side...
متن کاملThe Effect of Steroid Elution on the Performance of Coronary Sinus Leads for Left Ventricular Pacing in Dogs
Consistently low pacing thresholds of steroid-eluting leads are well documented for conventional lead positions [1-10], but not much comparative information is available on the extent and duration of the steroid effect in coronary sinus leads for left ventricular (LV) pacing. In this study, we compare the electrical performance of the coronary sinus leads Corox OTW steroid vs. Corox OTW (both B...
متن کاملPacing therapy in children.
BACKGROUND The importance of ventricular pacing site in pediatric pacemaker therapy has gradually become recognized. We reviewed our experience with a left ventricular (LV)-prioritized pacing strategy. METHODS AND RESULTS: Between 2000 and 2012, 60 patients underwent 76 permanent pacemaker implantations. Eight of the 29 reoperations involved ventricular lead repositioning for pacing-induced ven...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiology journal
دوره 20 4 شماره
صفحات -