Comparative Analysis of FBD and dq Current Detection Methods

نویسندگان

  • Wenjuan Li
  • Bo Jiang
  • Qi Yan
  • Pengshu Zhao
  • Dongyang Yang
چکیده

Current detection is the key to improve the power quality by using the active power filter. From two aspects which are algorithm of principle complexity and compensation for current harmonic content, this paper investigates to analyze and compare two novel harmonic current detection methods called FBD method and dq method. The results show that harmonic current can be well compensated by applications of the shunt active power filter with two methods. But FBD method has better prospects of a practical application for simpler algorithm, better real-time, and lower harmonic content after compensation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

کنترل کننده پیشفاز-پسفاز مقاوم برای تولیدات پراکنده در شرایط جزیره‌ای

Distributed generations that are connected to the network via a converter, employ dq current control method to control their active and reactive power components in grid-connected mode. In this paper a simple lead-lag control strategy is proposed for a distributed generation (DG) unit in island mode. When it is connected to the utility grid, the DG is controlled by a conventional dq-current con...

متن کامل

Applying Two Computational Classification Methods to Predict the Risk of Breast Cancer: A Comparative Study

Introduction: Lack of a proper method for early detection and diagnostic errors in medicine are some fundamental problems in treating cancer. Data analysis techniques may significantly help early diagnosis. The current study aimed at applying and evaluating neural networks and decision tree algorithm on breast cancer patients’ data for early cancer prediction. Methods: In the current stu...

متن کامل

Applying Two Computational Classification Methods to Predict the Risk of Breast Cancer: A Comparative Study

Introduction: Lack of a proper method for early detection and diagnostic errors in medicine are some fundamental problems in treating cancer. Data analysis techniques may significantly help early diagnosis. The current study aimed at applying and evaluating neural networks and decision tree algorithm on breast cancer patients’ data for early cancer prediction. Methods: In the current stu...

متن کامل

Electroanalysis of the Herbicide Diquat by Electrochemical Detector Containing Particles of Clay in Environmental Water

Clay modified carbon paste electrode (CPE-C) its applicability for electroanalysis of N, N’-ethylene-2,2’-bipyridinium (diquat) has been described in the present work. Electrochemical modification was performed by electronic impedance spectroscopy (EIS) and cyclic voltammetry (CV) in the range of -0.6 V to 1.2 V in 0.1 M K2SO4 (pH 3). The voltammetric method behavior of DQ is suggested where an...

متن کامل

Comparative Assessment of rEPC1 antigen and Copro-antigen for diagnosis of Echinococcosis in dogs

Abstract BACKGROUND: Diagnosis of Echinococcus granulosus in the definitive host particularly in dog is the significant complication in the endemic area. OBJECTIVES: The aim of this study is serological detection of E. granulosus in the infected dogs. METHODS: Dot-ELISA based on the copro-antigen and recombinant EPC1 antigen (rEPC1) for antibody detection was performed. Blood and fecal samples ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015