Simulating the effect of cochlear-implant electrode insertion depth on speech understanding.
نویسندگان
چکیده
Normally hearing listeners were presented with vowels, consonants, and sentences for identification through an acoustic simulation of a five-channel cochlear implant with electrodes separated by 4 mm (as in the Ineraid implant). The aim of the experiment was to simulate the effect of depth of electrode insertion on identification accuracy. Insertion depth was simulated by outputting sine waves from each channel of the processor at a frequency determined by the cochlear place of electrodes inserted 22-25 mm into the cochlea. The results indicate that simulated insertion depth had a significant effect on performance. Performance at 22- and 23-mm simulated insertion depths was always poorer than normal, and performance at 25 mm simulated insertion depth was, most generally, the same as normal. It is inferred from these results that, if insertion depth could be unconfounded from other coexisting factors in implant patients, then insertion depth would be found to affect speech identification performance significantly.
منابع مشابه
Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan
Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...
متن کاملAcoustic simulations of cochlear implants in human and machine hearing research
In this chapter, we review conventional uses of acoustic simulations in cochlear implants research and introduce novel applications of acoustic simulations of cochlear implants, both in cochlear implants research and in other domains, such as automatic speech recognition (ASR) research. In this respect, the first part of the chapter is dedicated in reviewing the conventional applications of aco...
متن کاملInteractions between cochlear implant electrode insertion depth and frequency-place mapping.
While new electrode designs allow deeper insertion and wider coverage in the cochlea, there is still considerable variation in the insertion depth of the electrode array among cochlear implant users. The present study measures speech recognition as a function of insertion depth, varying from a deep insertion of 10 electrodes at 28.8 mm to a shallow insertion of a single electrode at 7.2 mm, in ...
متن کاملEffect of cochlear implant electrode insertion on middle-ear function as measured by intra-operative laser Doppler vibrometry.
HYPOTHESIS The aim of this study was to investigate the impact of cochlear implant electrode insertion on middle-ear low frequency function in humans. BACKGROUND Preservation of residual low frequency hearing with addition of electrical speech processing can improve the speech perception abilities and hearing in noise of cochlear implant users. Preservation of low frequency hearing requires a...
متن کاملThe importance of electrode location in cochlear implantation
OBJECTIVES As indications for cochlear implantation have expanded to include patients with more residual hearing, increasing emphasis has been placed on minimally traumatic electrode insertion. Histopathologic evaluation remains the gold standard for evaluation of cochlear trauma, but advances in imaging techniques have allowed clinicians to determine scalar electrode location in vivo. This rev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of the Acoustical Society of America
دوره 102 5 Pt 1 شماره
صفحات -
تاریخ انتشار 1997