Assessing Image Quality and Estimating the Glandular Average Dose in Some Mammography Labs
نویسندگان
چکیده
Mammography is the safest method of detecting breast cancer but, at the same time, the most exacting radiological examination which implies getting high quality images and a minimum dose per breast. The present study was carried out in six mammography laboratories, from which only one has partially implemented a programme of quality control. There were evaluated the phantom image, film contrast, background optical density (OD), density difference (DD), radiation beam quality, and the entrance surface air kerma was measured. The glandular average dose was also estimated. Compared to the reference lab, all the other five labs failed all the tests, obtaining unacceptable results both for the phantom image and for the contrast, for the OD and DD. The average glandular doses estimated for the standard breast varied between 1.4 and 7.7 mSv, being in four out of the six hospitals, statistically significant (p < 0.001), lower or higher than those currently accepted by international authorities (3mSv). Such simple quality control procedures will improve the chances of accurate diagnosis and reduce the probability of false negatives. This is particularly important for early detection and treatment of breast cancer which is the highest type of cancer among females.
منابع مشابه
Evaluation of the relation between breast glandular absorbed dose and radiographic quality in mammography
Background: Breast is one of the main radiological sensitive organs, hence it is important to evaluate absorbed dose to this organ especially to the glandular parts. It is the aim of this study to measure mean glandular dose and image contrast in terms of different mammographic parameters. Materials and Methods: In this study two mammography machines located at Said-al Shohada (Giotto) ...
متن کاملEstimating average glandular dose in routine mammography screening using neural network
Given the extensive use of common mammography tests for screening and diagnosis of breast cancer, there are concerns over the increased dose absorbed by the patient due to the sensitivity of the breast tissue. Thus, knowing the Mean Glandular Dose (MGD) before radiation to the patient through its estimation can be helpful. For this reason, the MultiLayer Perceptron (MLP) neural network model wa...
متن کاملنتایج یک کُد فرترن برای محاسبه دوز غدهای در ماموگرافی با استفاده از پارامترهای Sobol-Wu
Background: Accurate computation of the radiation dose to the breast is essential to mammography. Various the thicknesses of breast, the composition of the breast tissue and other variables affect the optimal breast dose. Furthermore, the glandular fraction, which refers to the composition of the breasts, as partitioned between radiation-sensitive glandular tissue and the adipose tissue, also h...
متن کاملEstimation of Mean Estimation of Mean Glandular Dose in Mammography Examination in some of Radiology Centers in Tehran city
Introduction: the objectives of this research were determination of Mean Glandular Dose in film- screen and digital mammography examinations, estimation of accumulated effective dose in some of mammography centers in Tehran city and estimating cancer risk due to these examinations. Materials and Methods: the clinical data were collected from the 1318 <...
متن کاملCalculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography
Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...
متن کامل