Integrating monitor alarms with laboratory test results to enhance patient deterioration prediction
نویسندگان
چکیده
Patient monitors in modern hospitals have become ubiquitous but they generate an excessive number of false alarms causing alarm fatigue. Our previous work showed that combinations of frequently co-occurring monitor alarms, called SuperAlarm patterns, were capable of predicting in-hospital code blue events at a lower alarm frequency. In the present study, we extend the conceptual domain of a SuperAlarm to incorporate laboratory test results along with monitor alarms so as to build an integrated data set to mine SuperAlarm patterns. We propose two approaches to integrate monitor alarms with laboratory test results and use a maximal frequent itemsets mining algorithm to find SuperAlarm patterns. Under an acceptable false positive rate FPRmax, optimal parameters including the minimum support threshold and the length of time window for the algorithm to find the combinations of monitor alarms and laboratory test results are determined based on a 10-fold cross-validation set. SuperAlarm candidates are generated under these optimal parameters. The final SuperAlarm patterns are obtained by further removing the candidates with false positive rate>FPRmax. The performance of SuperAlarm patterns are assessed using an independent test data set. First, we calculate the sensitivity with respect to prediction window and the sensitivity with respect to lead time. Second, we calculate the false SuperAlarm ratio (ratio of the hourly number of SuperAlarm triggers for control patients to that of the monitor alarms, or that of regular monitor alarms plus laboratory test results if the SuperAlarm patterns contain laboratory test results) and the work-up to detection ratio, WDR (ratio of the number of patients triggering any SuperAlarm patterns to that of code blue patients triggering any SuperAlarm patterns). The experiment results demonstrate that when varying FPRmax between 0.02 and 0.15, the SuperAlarm patterns composed of monitor alarms along with the last two laboratory test results are triggered at least once for [56.7-93.3%] of code blue patients within an 1-h prediction window before code blue events and for [43.3-90.0%] of code blue patients at least 1-h ahead of code blue events. However, the hourly number of these SuperAlarm patterns occurring in control patients is only [2.0-14.8%] of that of regular monitor alarms with WDR varying between 2.1 and 6.5 in a 12-h window. For a given FPRmax threshold, the SuperAlarm set generated from the integrated data set has higher sensitivity and lower WDR than the SuperAlarm set generated from the regular monitor alarm data set. In addition, the McNemar's test also shows that the performance of the SuperAlarm set from the integrated data set is significantly different from that of the SuperAlarm set from the regular monitor alarm data set. We therefore conclude that the SuperAlarm patterns generated from the integrated data set are better at predicting code blue events.
منابع مشابه
Nursing assessment of continuous vital sign surveillance to improve patient safety on the medical/surgical unit
AIMS AND OBJECTIVES Evaluate continuous vital sign surveillance as a tool to improve patient safety in the medical/surgical unit. BACKGROUND Failure-to-rescue is an important measure of hospital quality. Patient deterioration is often preceded by changes in vital signs. However, continuous multi-parameter vital sign monitoring may decrease patient safety with an abundance of unnecessary alarm...
متن کاملCumulative Time Series Representation for Code Blue prediction in the Intensive Care Unit.
Patient monitors in hospitals generate a high number of false alarms that compromise patients care and burden clinicians. In our previous work, an attempt to alleviate this problem by finding combinations of monitor alarms and laboratory test that were predictive of code blue events, called SuperAlarms. Our current work consists of developing a novel time series representation that accounts for...
متن کاملPrediction of Clinical Deterioration in Hospitalized Adult Patients with Hematologic Malignancies Using a Neural Network Model
INTRODUCTION Clinical deterioration (ICU transfer and cardiac arrest) occurs during approximately 5-10% of hospital admissions. Existing prediction models have a high false positive rate, leading to multiple false alarms and alarm fatigue. We used routine vital signs and laboratory values obtained from the electronic medical record (EMR) along with a machine learning algorithm called a neural n...
متن کاملImpact of a Safety Huddle-Based Intervention on Monitor Alarm Rates in Low-Acuity Pediatric Intensive Care Unit Patients.
BACKGROUND Physiologic monitors generate high rates of alarms in the pediatric intensive care unit (PICU), yet few are actionable. OBJECTIVE To determine the association between a huddle-based intervention focused on reducing unnecessary alarms and the change in individual patients' alarm rates in the 24 hours after huddles. DESIGN Quasi-experimental study with concurrent and historical con...
متن کاملA team-based approach to reducing cardiac monitor alarms.
BACKGROUND AND OBJECTIVES Excessive cardiac monitor alarms lead to desensitization and alarm fatigue. We created and implemented a standardized cardiac monitor care process (CMCP) on a 24-bed pediatric bone marrow transplant unit. The aim of this project was to decrease monitor alarms through the use of team-based standardized care and processes. METHODS Using small tests of change, we develo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical informatics
دوره 53 شماره
صفحات -
تاریخ انتشار 2015