Atlantoaxial Transpedicular Screw Fixation for the Management of Traumatic Upper Cervical Spine Instability

نویسنده

  • Byung-Sub Kim
چکیده

Objective: The morbidity and mortality are high for traumatic upper cervical spine instability with cervico-medullary compression. In a clinical retrospective study, the clinical and radiographic results of occipitocervical (OC) fusion using posterior atlantoaxial transpedicular screw fixation in 12 patients with traumatic upper cervical spine instability was reviewed. Methods: Twelve patients with traumatic upper cervical spine instability (8 males and 4 females) were treated at our department over four years. Instability resulted from acute C1-C2 dislocation (4 cases), an acute unstable C2 fracture (1 case), acute C1-2-3 fracture dislocation (2 cases), acute C1 fracture (1 case), OC dislocation (2 cases) and old unstable C2 fracture (1 case). All 12 patients were internally fixed with occipital-/C1-C2 transpedicular screw fixation. The outcome (mean follow-up period, 16.5 months) was based on clinical and radiographic review using the Japanese Orthopedic Association (JOA) score. Results: Four neurologically intact patients remained the same after surgery. Among eight patients with cervical myelopathy, clinical improvement was noted in six cases (75%). The JOA score of the 8 patients were 9.4 (range, 0-16) before surgery and 12.1 (range, 0-17) with a recovery rate of 38.3% at the time of the last follow up. One patient died 2 months after the surgery because of pneumonia and sepsis. Fusion was achieved in 10 patients (90.9%) by the last follow-up. Conclusion: Early OC fusion is recommended in cases with traumatic upper cervical spinal instability, OC fusion with posterior atlantoaxial transpedicular screw fixation was a safe and effective method for the treatment of traumatic cervical spine instability. (J Kor Neurotraumatol Soc 2010;6:143-149)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

“Direct vision” operation of posterior atlantoaxial transpedicular screw fixation for unstable atlantoaxial fractures

BACKGROUND The posterior screw fixation in atlas via posterior arch and lateral mass, also called C1 "pedicle" screw, combined with C2 pedicle screw fixiation has shown better biomechanical stability in unstable atlantoaxial fractures. However, its popularization has to fulfill the limitation imposed by anatomical characteristics. The aim of this study was to explore the manipulation, effect, a...

متن کامل

Posterior occipito-axial fixation applied C2 laminar screws for pediatric atlantoaxial instability caused by Down syndrome: Report of 2 cases

BACKGROUND Upper cervical spine instability is one of the most critical orthopedic problems in patients with Down syndrome. However, arthrodesis of the upper cervical spine in these patients can be very difficult to achieve and has a high complication rate because of mental retardation and accompanying various medical conditions of the vital organs. Even now, surgeries in such patients, especia...

متن کامل

Screw Placement Accuracy and Outcomes Following O-Arm-Navigated Atlantoaxial Fusion: A Feasibility Study

Study Design Case series of seven patients. Objective C2 stabilization can be challenging due to the complex anatomy of the upper cervical vertebrae. We describe seven cases of C1-C2 fusion using intraoperative navigation to aid in the screw placement at the atlantoaxial (C1-C2) junction. Methods Between 2011 and 2014, seven patients underwent posterior atlantoaxial fusion using intraoperative ...

متن کامل

Migration of titanium cable into spinal cord and spontaneous C2 and C3 fusion

INTRODUCTION Atlantoaxial instability is a common and serious injury of the upper cervical spine. Brooks' procedure is widely used to reconstruct the unstable atlantoaxial joint. The migration into spinal cord of titanium cable and spontaneous fusion between C2 and C3 has been little reported and the management of such a patient is difficult. We describe an unusual case of fatigue failure of po...

متن کامل

Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report.

Thirteen patients with fractures and/or dislocations of the middle and lower cervical spine were treated by transpedicular screw fixation using the Steffee variable screw placement system. Postoperative immobilization was either not used or simplified to short-term use of a soft neck collar. Recovery of nerve function and correction of kyphotic and/or translational deformities were satisfactory...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010