Quality of cardiopulmonary resuscitation in out-of-hospital cardiac arrest before and after introduction of a mechanical chest compression device, LUCAS-2; a prospective, observational study

نویسندگان

  • Tinne Tranberg
  • Jens F Lassen
  • Anne K Kaltoft
  • Troels M Hansen
  • Carsten Stengaard
  • Lars Knudsen
  • Sven Trautner
  • Christian J Terkelsen
چکیده

BACKGROUND Mechanical chest compressions have been proposed to provide high-quality cardiopulmonary resuscitation (CPR), but despite the growing use of mechanical chest compression devices, only few studies have addressed their impact on CPR quality. This study aims to evaluate mechanical chest compressions provided by LUCAS-2 (Lund University Cardiac Assist System) compared with manual chest compression in a cohort of out-of-hospital cardiac arrest (OHCA) cases. METHODS In this prospective study conducted in the Central Denmark Region, Denmark, the emergency medical service attempted resuscitation and reported data on 696 non-traumatic OHCA patients between April 2011 and February 2013. Of these, 155 were treated with LUCAS CPR after an episode with manual CPR. The CPR quality was evaluated using transthoracic impedance measurements collected from the LIFEPAK 12 defibrillator, and the effect was assessed in terms of chest compression rate, no-flow time and no-flow fraction; the fraction of time during resuscitation in which the patient is without spontaneous circulation receiving no chest compression. RESULTS The median total episode duration was 21 minutes, and the episode with LUCAS CPR was significantly longer than the manual CPR episode, 13 minutes vs. 5 minutes, p < 0.001. The no-flow fraction was significantly lower during LUCAS CPR (16%) than during manual CPR (35%); difference 19% (95% CI: 16% to 21%; p < 0.001). No differences were found in pre- and post-shock no-flow time throughout manual CPR and LUCAS CPR. Contrary to the manual CPR, the average compression rate during LUCAS CPR was in conformity with the current Guidelines for Resuscitation, 102/minute vs. 124/minute, p < 0.001. CONCLUSION Mechanical chest compressions provided by the LUCAS device improve CPR quality by significantly reducing the NFF and by improving the quality of chest compression compared with manual CPR during OHCA resuscitation. However, data on end-tidal Co2 and chest compression depth surrogate parameters of CPR quality could not be reported.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prehospital randomised assessment of a mechanical compression device in cardiac arrest (PaRAMeDIC) trial protocol

BACKGROUND Survival after out-of-hospital cardiac arrest is closely linked to the quality of CPR, but in real life, resuscitation during prehospital care and ambulance transport is often suboptimal. Mechanical chest compression devices deliver consistent chest compressions, are not prone to fatigue and could potentially overcome some of the limitations of manual chest compression. However, ther...

متن کامل

Out-of-hospital cardiopulmonary resuscitation with the AutoPulse system: a prospective observational study with a new load-distributing band chest compression device.

OBJECTIVE To evaluate the effectiveness, the safety, and the practicability of the new automated load-distributing band resuscitation device AutoPulse in out-of-hospital cardiac arrest in the midsized urban emergency service of Bonn city. STUDY DESIGN Prospective, observational study. METHODS Measurements of effectiveness were the proportion of patients with a return of spontaneous circulat...

متن کامل

Chest compression rates during cardiopulmonary resuscitation are suboptimal: a prospective study during in-hospital cardiac arrest.

BACKGROUND Recent data highlight a vital link between well-performed cardiopulmonary resuscitation (CPR) and survival after cardiac arrest; however, the quality of CPR as actually performed by trained healthcare providers is largely unknown. We sought to measure in-hospital chest compression rates and to determine compliance with published international guidelines. METHODS AND RESULTS We deve...

متن کامل

Mechanical chest compression for out of hospital cardiac arrest: Systematic review and meta-analysis.

AIM To summarise the evidence from randomised controlled trials of mechanical chest compression devices used during resuscitation after out of hospital cardiac arrest. METHODS Systematic review of studies evaluating the effectiveness of mechanical chest compression. We included randomised controlled trials or cluster randomised trials that compared mechanical chest compression (using any devi...

متن کامل

Resuscitation quality assurance for out-of-hospital cardiac arrest--setting-up an ambulance defibrillator telemetry network.

BACKGROUND Out-of-hospital cardiac arrest (OHCA) is a leading cause of pre-hospital mortality. Chest compressions performed during cardiopulmonary resuscitation aim to provide adequate perfusion to the vital organs during cardiac arrest. Poor resuscitation technique and the quality of pre-hospital CPR influences outcome from OHCA. Transthoracic impedance (TTI) measurement is a useful tool in th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2015