Biocompatibility of hemodialysis membranes.
نویسنده
چکیده
Exposure of blood to hemodialysis membranes results in numerous interactions between the blood elements and the membrane. Transformation and adsorption of plasma proteins (such as complement) and activation of blood cells (such as neutrophils and monocytes) have been studied most extensively by nephrologists in recent years. There is no consensus on the definition of biocompatibility for dialyzer membranes. An operational definition of biocompatibility is the lack of any perturbation of blood constituents. According to this "inert surface" definition, a membrane (for example, one that adsorbs beta 2-microglobulin) can be considered as bioincompatible and yet desirable. Because of the multitude of blood-membrane interactions that may occur during hemodialysis, multiple criteria for biocompatibility needs to be applied in the classification of membranes. A certain bioincompatible phenomenon can be further classified as beneficial or deleterious depending on its biological effects as well as its acute and chronic impacts on the dialysis patient.
منابع مشابه
Advances in Polysulfone-Based Membranes for Hemodialysis
The polysulfone-based membrane has been used in hemodialysis (HD) and it is continuously developed to maintain its sustainability on the subject of biocompatibility. During the polysulfone-based membrane development, several parameters should be considered to improve the membrane performances, such as excellent biocompatibility, appropriate ultrafiltration rate, and effective clearance of the t...
متن کاملResolution of Dialyzer Membrane-Associated Thrombocytopenia with Use of Cellulose Triacetate Membrane: A Case Report
Blood and dialyzer membrane interaction can cause significant thrombocytopenia through the activation of complement system. The extent of this interaction determines the biocompatibility of the membrane. Although the newer synthetic membranes have been shown to have better biocompatibility profile than the cellulose-based membranes, little is known about the difference in biocompatibility betwe...
متن کاملComparison of Biocompatibility of Various Membranes with Fibroblasts
Objective: Different techniques have been suggested for the repair of bone defects at the injured sites. Use of biomembranes, or application of plasma rich in growth factor (PRGF) at the site of proliferation of osteoblasts are among the suggested techniques. The current study aimed to compare the biocompatibility of human periodontal ligament fibroblasts (hPLF) cultured on Hypro-Sorb F, Peri...
متن کاملVitamin E as a functional and biocompatibility modifier of synthetic hemodialyzer membranes: an overview of the literature on vitamin E-modified hemodialyzer membranes.
Along with one century of history, research has provided many solutions for hemodialysis (HD) biomaterials, encompassing several generations of copolymers that have found wide application in the development of hollow-fiber dialyzer membranes. Polysulfone-based biomaterials have gained increasing consideration and are now the gold standard in the production of biocompatible hemodialyzers. Howeve...
متن کاملIn Vivo Evaluation of the Biocompatibility of Surface Modified Hemodialysis Polysulfone Hollow Fibers in Rat
Polysulfone (Psf) hollow fiber membranes (HFMs) have been widely used in blood purification but their biocompatibility remains a concern. To enhance their biocompatibility, Psf/TPGS (d-α-tocopheryl polyethylene glycol 1000 succinate) composite HFMs and 2-methacryloyloxyethyl phosphorylcholine (MPC) coated Psf HFMs have been prepared. They have been evaluated for in vivo biocompatibility and gra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Society of Nephrology : JASN
دوره 1 2 شماره
صفحات -
تاریخ انتشار 1990