Influence of Transformer Layer Winding Parameters on the Capacitive Characteristic Coefficient
نویسندگان
چکیده
With changing the parameters of layer winding in transformers, capacitive characteristic coefficient of winding will be changed. Since, impulse voltage distribution (IVD) along a winding is depended on this coefficient, so analyzing this coefficient is important in transformers. This paper study and analyze a transformer with layer winding and rectangular cross-section. In this study, the influence of changing the layer winding transformers parameters (LWTP) on capacitive characteristic coefficient is going to be analyzed which may be a new research in this study. Also, in this study the equations for capacitances between winding turns in different layers and also equations for capacitances between turns and core in different layers are derived. The presented relationships are dependent on the parameters of the transformer winding, so changing these parameters will change turn-turn capacitance (TTC) and turn-core capacitance (TCC) and finally change the capacitances of the total series and parallel of the winding. The aim of this paper is to illustrate the effect of parameters deviations on the capacitances of the total series and parallel of the winding and show these effects on the results of the capacitive characteristic coefficient of the winding.
منابع مشابه
Influence of the Parameters of Disk Winding on the Impulse Voltage Distribution in Power Transformers
Overvoltage distribution along the transformer winding must be uniform to certify the safety of the operation of the power transformer. Influence of the parameters variation on the impulse voltage distribution (IVD) in disk winding transformer is going to be analyzed which hasn’t been analyzed on this type of winding in the previous papers. In this research, a transformer with disk winding and ...
متن کاملA Feasible Solution to Distinguish the Transformer Winding Deformation from Insulation Characteristic Impacts on FRA Spectrum
Frequency Response Analysis (FRA) is popular technique which has been used since the last decade as a diagnostic method for transformers. However, accurate interpretation of FRA measurements is still challenging. Recent studies reveal that apart from winding deformation, FRA data can also be influenced by moisture variation in transformer paper insulation. Hence, a specific transformer’s model ...
متن کاملInternal Protection of Transformer Windings Against Transeint Surges Using ZnO Varistors
Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...
متن کاملCharacterization of Power Transformer Electromagnetic Forces Affected by Winding Faults
Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...
متن کاملInternal Protection of Transformer Windings Against Transeint Surges Using ZnO Varistors
Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...
متن کامل