Evaluation of an antimicrobial surgical glove to inactivate live human immunodeficiency virus following simulated glove puncture.
نویسندگان
چکیده
BACKGROUND Percutaneous injuries associated with cutting instruments, needles, and other sharps (eg, metallic meshes, bone fragments, etc) occur commonly during surgical procedures, exposing members of surgical teams to the risk for contamination by blood-borne pathogens. This study evaluated the efficacy of an innovative integrated antimicrobial glove to reduce transmission of the human immunodeficiency virus (HIV) following a simulated surgical-glove puncture injury. METHODS A pneumatically activated puncturing apparatus was used in a surgical-glove perforation model to evaluate the passage of live HIV-1 virus transferred via a contaminated blood-laden needle, using a reference (standard double-layer glove) and an antimicrobial benzalkonium chloride (BKC) surgical glove. The study used 2 experimental designs. In method A, 10 replicates were used in 2 cycles to compare the mean viral load following passage through standard and antimicrobial gloves. In method B, 10 replicates were pooled into 3 aliquots and were used to assess viral passage though standard and antimicrobial test gloves. In both methods, viral viability was assessed by observing the cytopathic effects in human lymphocytic C8166 T-cell tissue culture. Concurrent viral and cell culture viability controls were run in parallel with the experiment's studies. RESULTS All controls involving tissue culture and viral viability were performed according to study design. Mean HIV viral loads (log(10)TCID(50)) were significantly reduced (P < .01) following passage through the BKC surgical glove compared to passage through the nonantimicrobial glove. The reduction (log reduction and percent viral reduction) of the HIV virus ranged from 1.96 to 2.4 and from 98.9% to 99.6%, respectively, following simulated surgical-glove perforation. CONCLUSION Sharps injuries in the operating room pose a significant occupational risk for surgical practitioners. The findings of this study suggest that an innovative antimicrobial glove was effective at significantly (P < .01) reducing the risk for blood-borne virus transfer in a model of simulated glove perforation.
منابع مشابه
Antibacterial activity of a sterile antimicrobial polyisoprene surgical glove against transient flora following a 2-hours simulated use
BACKGROUND A surgical glove will protect surgeons and patients only if the glove's integrity remains intact. However, several studies have demonstrated that undetected micro-perforations of surgical gloves are common. Because of the possibility of surgical glove puncture, an antimicrobial surgical glove was developed. The aim of this laboratory based experimental study was to assess the antibac...
متن کاملStandardization of needlestick injury and evaluation of a novel virus-inhibiting protective glove.
Rubber surgical gloves worn as a barrier to prevent contamination from body fluids offer relative protection against contamination through direct percutaneous injuries involving needles, scalpel blades or bone fragments. To determine the main experimental parameters influencing the volume of blood transmitted by a hollow-bore needle (worst case scenario) during an accidental puncture, we design...
متن کاملEvaluation of an innovative antimicrobial surgical glove technology to reduce the risk of microbial passage following intraoperative perforation.
BACKGROUND Surgical gloves provide a protective barrier for patients and members of the surgical team. Although glove integrity is important in an era of blood-borne pathogens, little data exist on bacterial passage after glove perforation. This study evaluated the impact of antimicrobial surgical gloves in reducing microbial passage after glove puncture in a model of wound contamination. MET...
متن کاملUsing innovative antimicrobial glove technology to reduce the risk of surgical wound contamination following glove perforation
Introduction / objectives Surgical gloves create a protective barrier, however high perforation rates (6%>60%) are reported in the literature. A recent study has suggested linkage between glove perforation and increased risk of SSI. This investigation evaluated a model of microbial passage through conventional single (A), double-thickness (B) and a tri-layer innovative surgical glove (C) with a...
متن کاملUsing a SCIP-PLUS perspective to reduce the risk of SSI
Methods Four risk reduction initiatives were studied, A: Impact of BMI on antimicrobial prophylactic dosing in general, OB and CT surgical patients; B: Development of standardized regimen of CHG preadmission cleansing to improve outcome in surgical patients; C: Efficacy of antimicrobial sutures to reduce the risk of suture contamination at wound closure and D: The impact of an innovative antimi...
متن کاملذخیره در منابع من