Gas generation and clot formation during electrolytic detachment of Guglielmi detachable coils: in vitro observations and animal experiment.

نویسندگان

  • Moon Hee Han
  • O-Ki Kwon
  • Chang Jin Yoon
  • Bae Joo Kwon
  • Sang Hoon Cha
  • Kee-Hyun Chang
چکیده

BACKGROUND AND PURPOSE Recent reports describe a high rate of thromboembolic events related to Guglielmi detachable coil (GDC) use in the treatment of cerebral aneurysms. The purpose of this study was to investigate electrolysis-related changes of blood as a potential cause of thromboembolic complications associated with GDC use. METHODS For in vitro observations, 15 GDCs (10 conventional coils and five insulated coils) were experimentally detached under microscopic observation. Three coils were detached in normal saline, five in human serum, and seven in heparinized human blood. For animal experiments, two coils were detached in two canine normal common carotid arteries with systemic heparinization. Immediately after detachment, the arteries were exposed, and clot formations were observed. RESULTS Significant amounts of gas bubbles were observed in all in vitro observations; more were seen in conventional coils, which required longer detachment times, than in insulated coils. Gas generation started with the growth of tiny bubbles into larger ones. In insulated coils, gas was generated only at the detachment zone, and no difference between saline, serum, and blood environments was observed. During detachment within heparinized blood, clot formations of 2-3-mm diameter were observed at the detachment zones of insulated coils. Animal experiments showed clot formation at the detachment zone, and bubble entrapments around the clots were also found. CONCLUSION The electrolytic detachment mechanism of the platinum coil can generate gas bubbles during the application of electric current. In association with electrothrombosis, this phenomenon may be a potential cause of thromboembolic complications during the treatment of cerebral aneurysms by use of GDCs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thromboembolic Events Associated with Electrolytic Detachment of Guglielmi Detachable Coils and Target Coils : Comparison with Use of Diffusion-Weighted MR Imaging

OBJECTIVE The purpose of this study was to retrospectively evaluate and compare the incidence of diffusion-weighted image (DWI) lesions between the Guglielmi detachable coil (GDC) and the Target coil for treating unruptured intracranial aneurysm. METHODS From 2010 to 2011, consecutive 222 patients with an intracranial aneurysm underwent coil embolization. Inclusion criterias were : 1) unruptu...

متن کامل

Technical problems associated with new designs of Guglielmi detachable coils.

BACKGROUND AND PURPOSE Recently, we experienced several technical problems that were directly related to new designs of Guglielmi detachable coils (GDCs). We herein present cases involving those problems and propose probable causes. METHODS We reviewed the clinical and angiographic data of 269 consecutive patients with intracranial aneurysms who had been treated with GDCs between May 1996 and...

متن کامل

Topic review: surface modifications enhancing biological activity of guglielmi detachable coils in treating intracranial aneurysms.

BACKGROUND Endovascular therapy with Guglielmi detachable coils is an accepted treatment option for patients with intracranial aneurysms. However, an emerging technology in the realm of endovascular tools is the use of traditional Guglielmi detachable coils with biologically active substances complexed to the coil surface to enhance aneurysm occlusion. METHODS We review the literature and cur...

متن کامل

MR artifacts, heat production, and ferromagnetism of Guglielmi detachable coils.

The Guglielmi detachable coil, a platinum microcoil used in the endovascular treatment of intracranial aneurysms, was studied in vitro for its MR imaging artifacts, heat production, and ferromagnetism. In addition, imaging artifacts were studied in vivo in eight patients who had undergone therapeutic placement of these coils. These devices displayed a very low level of MR artifact and no ferrom...

متن کامل

Thromboembolic complications of endovascular aneurysm occlusion using matrix detachable coils.

Thromboembolic Complications of Endovascular Aneurysm Occlusion Using Matrix Detachable Coils To the Editor: We read with great interest the article by Taschner et al.1 The authors presented their philosophy in case selection for aneurysm occlusion using matrix detachable coils and their clinical results. Of the 25 total procedures, 5 were complicated with a thrombus formation in the parent art...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 24 3  شماره 

صفحات  -

تاریخ انتشار 2003