Comparison and Evaluation of DRI | Methamphetamine , DRI Ecstasy , Abuscreen | ONLINE Amphetamine

نویسنده

  • Peter R. Stout
چکیده

I The performances of four immunoassays (DRI amphetamines, DRI ecstasy, Abuscreen ONLINE amphetamines, and a modified Abuscreen ONLINE amphetamines) were evaluated for control failure rates, sensitivily, and specificity for amphetamine (AMP), methamphetamine (MTH), 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphelamine (MDMA). The two DRI reagents and the ONLINE reagents were run according to manufacturer specifications using a Roche Hitachi Modular DDP system. The modified ONLINE reagent was calibrated with MDMA and had 16raM sodium periodate added to the R2 reagent. These assays were run on approximately 27,500 human urine samples and 7000 control urine samples prepared at 350 and 674 ng/mL over the course of 8 days. All assays were calibrated using a single point, qualitative cutoff standard with the manufacturerrecommended compound at the Department of Defense cutoff (500 ng/mL). Gas chromatography-mass spectrometry (GC-MS) confirmation was conducted on screened-positive samples. Control performance for the manufacturer recommended assays was excellent, with a maximum qualitative control failure rate of 2.03%. The modified ONLINE reagent demonstrated poor control performance with a maximum failure rate of 38.3% and showed no improved MDMA sensitivity when compared with the ONLINE reagent; the confirmation rate (20%) was improved when compared with the production ONLINE reagent (8%). The DRI ecstasy reagent provided improved sensitivity for MDMA as 9 The opinions contained in the publication are not to be construed as official or as reflecting the views of the Department of Defense or the Department of the Navy, compared with the ONLINE reagent, with approximately 23% more samples screening and confirming positive for MDMA and a confirmation rate of approximately 90%. The DRI methamphetamine reagent had a low confirmation rate (6% or less) and produced numerous positives for samples with only ephedrine or pseudoephedrine present.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Immunoassays for the Determination of MDMA and Cannabinoids in Urine Samples

Methylenedioxymethamphetamine (MDMA) is structurally related to methamphetamine (MA). There are many different commercially available immunoassay (IA) reagents for the initial screening of amphetamine and/or methamphetamine. These reagents may be employed to detect MDA/MDMA in urine samples. In order to select a suitable reagent for the initial screening of MDMA in urine samples, we evaluated 7...

متن کامل

Evaluation of Roche Abuscreen ONLINE amphetamine immunoassay for screening of new amphetamine analogues.

Some structural analogues of amphetamine are now important drugs of abuse in Thailand. The utility of the Roche Abuscreen ONLINE reagent amphetamine immunoassay test kit to detect these analogues was studied. The test showed high cross-reactivity to 3,4-methylenedioxyamphetamine (MDA), but low cross-reactivity to its parent drugs, 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxye...

متن کامل

Profiles of urine samples taken from Ecstasy users at Rave parties: analysis by immunoassays, HPLC, and GC-MS.

The abuse of the designer amphetamines such as 3,4-methylenedioxymethamphetamine (MDMA, Ecstasy) is increasing throughout the world. They have become popular drugs, especially at all-night techno dance parties (Raves), and their detection is becoming an important issue. Presently, there are no MDMA- or MDA-specific immunoassays on the market, and detection of the designer amphetamines is depend...

متن کامل

Determination of designer drug cross-reactivity on five commercial immunoassay screening kits.

The detection of new designer drugs is often a difficult issue in forensic urine drug testing as immunoassays are the primary screening methodology for drugs of abuse in many of these laboratories. Cross-reactivity of compounds with immunoassay kits can either aid or complicate the detection of a variety of drug and drug metabolites. For instance, emerging designer drugs that share structural s...

متن کامل

Evaluation of the Triage PPY on-site testing device for the detection of dextropropoxyphene in urine.

A new point-of-care colloidal metal immunoassay urine drugs-of-abuse testing device, the BIOSITE TRIAGE Plus Propoxyphene (TPP), was evaluated for the rapid detection of dextropropoxyphene (PPY) and/or its primary metabolite, norpropoxyphene (NP), in urine at a total PPY/NP concentration of 300 ng/mL or greater. This assay has been added to the Triage device that tests for commonly abused drugs...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012