Virtual prototyping of a semi-active transfemoral prosthetic leg.
نویسندگان
چکیده
This article presents a virtual prototyping study of a semi-active lower limb prosthesis to improve the functionality of an amputee during prosthesis-environment interaction for level ground walking. Articulated ankle-foot prosthesis and a single-axis semi-active prosthetic knee with active and passive operating modes were considered. Data for level ground walking were collected using a photogrammetric method in order to develop a base-line simulation model and with the hip kinematics input to verify the proposed design. The simulated results show that the semi-active lower limb prosthesis is able to move efficiently in passive mode, and the activation time of the knee actuator can be reduced by approximately 50%. Therefore, this semi-active system has the potential to reduce the energy consumption of the actuators required during level ground walking and requires less compensation from the amputee due to lower deviation of the vertical excursion of body centre of mass.
منابع مشابه
Virtual Constraint Control of a Powered Prosthetic Leg: Experiments with Transfemoral Amputees
Powered prosthetic legs could significantly improve mobility for lower-limb amputees, but the performance and clinical viability of these devices are currently limited by complex control systems that independently control different joints and time periods of the gait cycle. Recent efforts have been made to address these challenges with a unifying control model used by recent bipedal robots, in ...
متن کاملAssessment of transfemoral amputees using C-Leg and Power Knee for ascending and descending inclines and steps.
Adding active power to a prosthetic knee unit may improve function and reduce the potential for overuse injuries in persons with transfemoral amputation (TFA). Servicemembers who have sustained a TFA are often young and motivated to perform at high functional levels. The goal of this article is to compare the biomechanics of ramp and stair descent and ascent for participants using the C-Leg and...
متن کاملAssessment of transfemoral amputees using a passive microprocessor-controlled knee versus an active powered microprocessor-controlled knee for level walking
BACKGROUND In transfemoral (TF) amputees, the forward propulsion of the prosthetic leg in swing has to be mainly carried out by hip muscles. With hip strength being the strongest predictor to ambulation ability, an active powered knee joint could have a positive influence, lowering hip loading and contributing to ambulation mobility. To assess this, gait of four TF amputees was measured for lev...
متن کاملAssessing the Relative Contributions of Active Ankle and Knee Assistance to the Walking Mechanics of Transfemoral Amputees Using a Powered Prosthesis
Powered knee-ankle prostheses are capable of providing net-positive mechanical energy to amputees. Yet, there are limitless ways to deliver this energy throughout the gait cycle. It remains largely unknown how different combinations of active knee and ankle assistance affect the walking mechanics of transfemoral amputees. This study assessed the relative contributions of stance phase knee swing...
متن کاملMechanical work performed by individual limbs of transfemoral amputees during step-to-step transitions: Effect of walking velocity.
The greater metabolic demand during the gait of people with a transfemoral amputation limits their autonomy and walking velocity. Major modifications of the kinematic and kinetic patterns of transfemoral amputee gait quantified using gait analysis may explain their greater energy cost. Donelan et al. proposed a method called the individual limb method to explore the relationships between the ga...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
دوره 229 5 شماره
صفحات -
تاریخ انتشار 2015