A Biomechanical Study Comparing Helical Blade with Screw Design for Sliding Hip Fixations of Unstable Intertrochanteric Fractures

نویسندگان

  • Qiang Luo
  • Grace Yuen
  • Tak-Wing Lau
  • Kelvin Yeung
  • Frankie Leung
چکیده

Dynamic hip screw (DHS) is a well-established conventional implant for treating intertrochanteric fracture. However, revision surgery sometimes still occurs due to the cutting out of implants. A helical blade instead of threaded screw (DHS blade) was designed to improve the fixation power of the osteoporotic intertrochanteric fracture. In this study, the biomechanical properties of DHS blade compared to the conventional DHS were evaluated using an unstable AO/OTA 31-A2 intertrochanteric fracture model. Fifty synthetic proximal femoral bone models with such configuration were fixed with DHS and DHS blade in five different positions: centre-centre (CC), superior-centre (SC), inferior-center (IC), centre-anterior (CA), and centre-posterior (CP). All models had undergone mechanical compression test, and the vertical and rotational displacements were recorded. The results showed that DHS blade had less vertical or rotational displacement than the conventional DHS in CC, CA, and IC positions. The greatest vertical and rotational displacements were found at CP position in both groups. Overall speaking, DHS blade was superior in resisting vertical or rotational displacement in comparison to conventional DHS, and the centre-posterior position had the poorest performance in both groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: a biomechanical evaluation.

OBJECTIVE To compare the fixation stability in the femoral head with sliding hip screw versus helical blade designs for unstable, intertrochanteric hip fractures. METHODS A simulated, unstable intertrochanteric hip fracture was created in six pairs of cadaveric femurs. One of each pair was treated using an intramedullary nail with a sliding hip screw (ITST) for femoral head fixation and the o...

متن کامل

Measurement of Tip Apex Distance and Migration of Lag Screws and Novel Blade Screw Used for the Fixation of Intertrochanteric Fractures

Fixation with a dynamic hip screw (DHS) is one of the most common methods for stabilizing intertrochanteric fractures, except for unstable and reverse oblique fracture types. However, failure is often observed in osteoporotic patients whereby the lag screw effectively 'cuts out' through the weak bone. Novel anti-migration blades have been developed to be used in combination with a lag screw ('B...

متن کامل

Commentary: Morphology and fixation pitfalls of a highly unstable intertrochanteric fracture variant.

fractures with an intact posteromedial buttress, have been successfully treated with a sliding hip screw or blade.1 However, unstable intertrochanteric fractures tend to collapse even after adequate reduction and fixation with plating, and thus intramedullary nailing is recommended.2 Unstable intertrochanteric fractures include fractures with posteromedial comminution, a reverse oblique configu...

متن کامل

How to Treat the Complex Unstable Intertrochanteric Fractures in Elderly Patients? DHS or Arthroplasty

Background:  Due to difficulty in obtaining anatomical reduction, management of the unstable intertrochanteric fractures in elderly osteoporotic patients is challenging. The purpose of this study is to compare the results of hip arthroplasty (total, hemi, or bipolar) with DHS in the elderly patients with unstable intertrochanteric fractures.   Methods:  We prospectively studied and followed-up ...

متن کامل

Factors influencing functional outcomes in united intertrochanteric hip fractures: a negative effect of lag screw sliding.

The purpose of this study was to investigate the factors influencing functional outcomes in elderly patients with united intertrochanteric fractures treated with hip nails and to ascertain whether decreased femoral offset due to lag screw sliding has a negative effect on functional outcomes in these patients. This retrospective study included 65 patients older than 65 years with united intertro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013