An amperometric cholesterol biosensor based on epoxy resin membrane bound cholesterol oxidase
نویسندگان
چکیده
BACKGROUND & OBJECTIVES The use of epoxy resin membrane as a support for immobilization of enzyme has resulted into improved sensitivity and stability of biosensors for uric acid, ascorbic acid and polyphenols. The present work was aimed to prepare an improved amperometric biosensor for determination of serum cholesterol required in the diagnostics and management of certain pathological conditions. METHODS Epoxy resin membrane with immobilized cholesterol oxidase was mounted on the cleaned platinum (Pt) electrode with a parafilm to construct a working electrode. This working electrode along with Ag/AgCl as reference and Ag wire as an auxiliary electrode were connected through a three terminal electrometer to construct a cholesterol biosensor. RESULTS The sensor showed optimum response within 25 sec at pH 7.0 and 45°C. The linear working range of biosensor was 1.0 to 8.0 mM cholesterol. K m and I max for cholesterol were 5.0 mM and 9.09 μA, respectively. The biosensor measured serum cholesterol. The minimum detection limit of the sensor was 1.0 mM. The mean analytical recoveries of added cholesterol in serum (2.84 and 4.13 mM) were 91.4 ± 2.8 and 92.3 ± 3.1 per cent (n=6), respectively. Within and between assay coefficient of variation (CV) were <2 and <4 per cent, respectively. Biosensor had a storage life of 6 months at 4 o C. INTERPRETATION & CONCLUSIONS The use of epoxy resin membrane as a support for immobilization of cholesterol oxidase has resulted into an improved amperometric cholesterol biosensor. The present biosensor had an advantage over the existing biosensors as it worked at comparatively lower potential.
منابع مشابه
Carbon Nanotube Based Amperometric Biosensor for the Quantitative Detection of Cholesterol
A high sensitive and stable amperometric biosensor was developed using cholesterol oxidase, chitosan and multiwall carbon nano tubes (MWCNT’s) in order to determine total cholesterol in serum samples. Cholesterol oxidase was covalently immobilized on MWCNT’s; this enzyme was coated over glassy carbon electrode (GCE) and then a layer of chitosan deposited to prevent enzyme leaching. The ChOx/MWC...
متن کاملConstruction of an amperometric triglyceride biosensor using PVA membrane bound enzymes.
OBJECTIVES A method is described for construction of an amperometric triglyceride (TG) biosensor using PVA membrane bound enzymes. DESIGN AND METHODS A mixture of commercial lipase, glycerol kinase, glycerol-3-phosphate oxidase and horseradish peroxidase was co-immobilized onto polyvinyl alcohol (PVA) membrane through glutaraldehyde coupling. The biosensor measures current when polarized at 0...
متن کاملDevelopment of a platinized and ferrocene-mediated cholesterol amperometric biosensor based on electropolymerization of polypyrrole in a flow system.
The preparation of a cholesterol amperometric biosensor using a platinized Pt electrode as a support for the electropolymerization of a polypyrrole film, in which cholesterol oxidase and ferrocene monocarboxylic acid (electron-transfer mediator) were co-entrapped, is described. All the biosensor preparation steps (platinization and electropolymerization) and the cholesterol determination take p...
متن کاملVIKAS & PUNDIR: FABRICATION OF Pt BASED AMPEROMETRIC CHOLESTEROL BIOSENSOR
Cholesterol esterase, cholesterol oxidase and horseradish peroxidase (HRP) have been co-immobilized onto cellulose acetate membrane, which is mounted over biosensor, Pt electrode. Biosensor showes excellent performance with a linear response between 2.5 to 50 mg dl of cholesterol acetate [correlation coefficient (r) = 0.9912]. Mean analytical recovery of added cholesteryl acetate (100 and 200 m...
متن کاملPreparation of a Polypyrrole-Polyvinylsulphonate Composite Film Biosensor for Determination of Cholesterol Based on Entrapment of Cholesterol Oxidase
In this paper, a novel amperometric cholesterol biosensor with immobilization of cholesterol oxidase on electrochemically polymerized polypyrrole-polyvinylsulphonate (PPy-PVS) films has been accomplished via the entrapment technique on the surface of a platinum electrode. Electropolymerization of pyrrole and polyvinylsulphonate on the Pt surface was carried out by cyclic voltammetry between -1....
متن کامل