Reliability and feasibility of methods to quantitatively assess peripheral edema.
نویسندگان
چکیده
OBJECTIVE To evaluate methods to assess peripheral edema for reliability, feasibility and correlation with the classic clinical assessment of pitting edema. DESIGN Cross-sectional observational study. SETTING Large primary care clinic in Marshfield, Wisconsin, USA. PARTICIPANTS Convenience sample of 20 patients with type 2 diabetes and a range of edema severity, including patients without edema. METHODS Eight methods of edema assessment were evaluated: (1) clinical assessment of pit depth and recovery at three locations, (2) patient questionnaire, (3) ankle circumference, (4) figure-of-eight (ankle circumference using eight ankle/foot landmarks), (5) edema tester (plastic card with holes of varying size pressed to the ankle with a blood pressure cuff), (6) modified edema tester (edema tester with bumps), (7) indirect leg volume (by series of ankle/leg circumferences), and (8) foot/ankle volumetry by water displacement. Patients were evaluated independently by three nurse examiners. RESULTS Water displacement and ankle circumference had high inter-examiner agreement (intraclass correlation coefficient 0.93, 0.96 right; 0.97, 0.97 left). Agreement was inconsistent for figure-of-eight (0.64, 0.86), moderate for indirect leg volume (0.53, 0.66), and low for clinical assessments at all locations. Agreement was low for the edema testers but varied by the pressure administered. Correlation with the classic, subjective clinical assessment was good for the nurse-performed assessments and patient questionnaire. Ankle circumference and patient questionnaires each took 1 minute to complete. Other tools took >5 minutes to complete. CONCLUSIONS Water displacement and ankle circumference showed excellent reliability; however, water displacement is a time-consuming measure and may pose implementation challenges in the clinical and clinical trial environments. Patient-reported level and frequency of edema, based on an unvalidated questionnaire, was generally well correlated with the physician assessment of edema severity and may prove to be another reliable and accurate method of assessing edema. Additional study is needed to evaluate the validity and responsiveness of these methods.
منابع مشابه
Pharmacokinetic study of furosemide incorporated PLGA microspheres after oral administration to rat
Objective(s): The purpose of the current study was to assess the feasibility of microspheres from biocompatible polymer for oral bioavailability (BA) enhancement of potent sulfonamide- type loop diuretic- Furosemide - which used in the treatment of congestive heart failure, caused edema, cirrhosis, renal disease and as an adjunct in acute pulmonary edema. The comparatively poor and inconstant B...
متن کاملThe effect of low-level laser therapy on complications after crown lengthening surgery-A double-blind clinical trial
Background & aim: The formation and persistence of surgical wounds can cause a variety of complications, including pain, swelling, inflammation, re-infection, dysfunction, delay in the healing process and aesthetic problems. So far, various methods have been proposed to reduce these complications, one of which is the use of low-level lasers. The aim of this study was to investigate the effect o...
متن کاملTeachers’ and Students’ Satisfaction with DOPS Examination in Islamic Azad University of Mashhad, a Study in Year 2012
Introduction: Assessment is an essential and integral part of medicine. In addition to validity and reliability, a desirable method for student evaluation should leave a positive effect on student’s learning and be feasible and acceptable by students and teachers. Hence, this study aimed to survey students’ and teachers’ satisfaction with DOPS examination. Methods: This experimental study used...
متن کاملFeasibility of Implementing Blockchain and Internet of Things Technologies in Hospitals Affiliated to Tabriz University of Medical Sciences
Objective Considering the importance of implementing Internet of Thing (IoT) and blockchain technologies in the health sector, and the need to assess the feasibility of each project before implementation, this study aims to assess feasibility of implementing blockchain and IoT technologies in hospitals affiliated to Tabriz University of Medical Sciences. Methods This cross-sectional study was ...
متن کاملAcute Hemorrhagic Edema of Infancy: Report of Two Cases Report
Introducon: Acute hemorrhagic edema of infancy (AHEI) is a cutaneous leukocytoclas!c vasculi!s of infants, clinically characterized by acute development of peripheral edema and targetoid purpuric lesions on face and extremi!es. It is considered to be an uncommon form of cutaneous vasculi!s occurring in children younger than 2 years old. The clinical picture has a violent onset, a short beni...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical medicine & research
دوره 7 1-2 شماره
صفحات -
تاریخ انتشار 2009