Reproducibility of coronary vessel wall imaging techniques
نویسندگان
چکیده
Background Coronary wall thickness measurements must be highly reproducible to be useful in longitudinal studies. While 2D turbo-spin-echo (TSE) and spiral techniques are commonly used, 3D techniques reduce partial-volume effects and allow greater vessel coverage. Recently, 3D coronary wall imaging was demonstrated with 100% respiratory efficiency (RE) using beat-to-beat respiratory motion correction (B2B-RMC) [1] which uses motion information determined from low resolution 3D images of the fat around the vessel as a surrogate for vessel motion. Here we assess the reproducibility of this technique together with that of navigator-gated 2D TSE and spiral acquisitions. Methods Cross-sectional right coronary artery wall images were obtained in 10 healthy subjects on a Siemens 1.5T Avanto scanner using dark-blood prepared B2B-RMC 3D spiral imaging, navigator-gated 2D TSE imaging and navigator-gated 2D spiral imaging. Acquisition order was randomized and subjects were imaged on two separate occasions to assess inter-study reproducibility using the intra-class correlation-coefficient (ICC) and Bland Altman analysis. All acquisitions used 0.7x0.7mm inplane resolution. B2B-RMC 3D spiral acquisitions acquired 8x3.0mm slices (16x1.5mm reconstructed) and 2D techniques acquired 1x6mm slice. Navigator-gated techniques used a 5mm window while B2B-RMC excluded data acquired at only very extreme respiratory positions, retrospectively correcting the rest. Durations, assuming 100% RE, were 600 cardiac cycles (CC) for B2B-RMC, 75CC for 2D spiral and 202-576CC for 2D
منابع مشابه
High-resolution 3D coronary vessel wall imaging with near 100% respiratory efficiency using epicardial fat tracking: reproducibility and comparison with standard methods.
PURPOSE To quantitatively assess the performance and reproducibility of 3D spiral coronary artery wall imaging with beat-to-beat respiratory-motion-correction (B2B-RMC) compared to navigator gated 2D spiral and turbo-spin-echo (TSE) acquisitions. MATERIALS AND METHODS High-resolution (0.7 × 0.7 mm) cross-sectional right coronary wall acquisitions were performed in 10 subjects using four techn...
متن کاملReproducibility of 3D free-breathing magnetic resonance coronary vessel wall imaging.
AIMS Although the coronary artery vessel wall can be imaged non-invasively using magnetic resonance imaging (MRI), the in vivo reproducibility of wall thickness measures has not been previously investigated. Using a refined magnetization preparation scheme, we sought to assess the reproducibility of three-dimensional (3D) free-breathing black-blood coronary MRI in vivo. METHODS AND RESULTS MR...
متن کاملTime-Efficient Black Blood RCA Wall Imaging at 3T Using Improved Motion Sensitized Driven Equilibrium (iMSDE): Feasibility and Reproducibility
BACKGROUND The aim of this study was to explore the feasibility and reproducibility of a time-efficient coronary vessel wall measurement approach using an improved motion-sensitized driven equilibrium (iMSDE) pulse sequence. METHODOLOGY In this study, the iMSDE pulse sequence was first optimized and then applied on a group of healthy volunteers (N = 10) to evaluate its feasibility of vessel w...
متن کاملReproducibility of black-blood coronary vessel wall MR imaging.
PURPOSE New magnetic resonance imaging (MRI) methods can provide high spatial resolution images of the coronary artery wall, and statistically significant differences in coronary vessel wall thickness between atherosclerotic disease patients and control subjects have been shown. The aim of this study is to assess inter-study reproducibility (i.e., repeatability) of the cross-sectional 2D corona...
متن کاملHigh resolution 3D spiral coronary vessel wall imaging with >99% respiratory efficiency using beat to beat respiratory motion correction: quantitative comparison with navigator gated 2D spiral and turbo spin echo imaging
Introduction: Dark blood coronary artery wall imaging has demonstrated the ability to detect vessel wall thickening in subjects with non-significant coronary heart disease [1]. For high resolution imaging, studies are generally performed with diaphragmatic navigator gating which has an inherently low respiratory efficiency (RE) and is further compromised by respiratory drift through the long ac...
متن کامل