UVC fluencies for preventative treatment of Pseudomonas aeruginosa contaminated polymer tubes.
نویسندگان
چکیده
Exposing Pseudomonas aeruginosa biofilm grown on the inner surface of Teflon and silicone tubes to UVC light (265 nm) from light emitting diodes (LED) has previously been shown to substantially reduce biofilm growth. Smaller UVC fluencies were required to disinfect Teflon tubes compared to silicone tubes. Light propagation enhancement in tubes can be obtained if the refractive index of the intra-luminal saline solution is higher than that of the polymer. This condition is achieved by using Teflon tubes with a low refractive index (1.34) instead of the polymers with a high refractive index (1.40-1.50) normally used for tubing in catheter production. Determining whether or not UVC light exposure can disinfect and maintain the intra-luminal number of colony forming units (CFUs) at an exceedingly low level and thus avoid the growth and establishment of biofilm is of interest. The use of UVC diodes is demonstrated to be a preventative disinfection treatment on tubes made of Teflon, which enhances the UVC light propagation, and on tubes made of a softer material, ethylene vinyl acetate (EVA), which is suitable for catheters but much less suitable for UVC light propagation. Simulating an aseptic breach (∼10(3)-10(4) CFU ml(-1)), the UVC disinfection set-up was demonstrated using tubes contaminated with planktonic P. aeruginosa. After the tubes (10-20 cm) were inoculated with the bacterial solution for 3 h, they were emptied and filled with saline solutions (0.9-20%). Next UVC fluencies (0-21 mJ cm(-2)) were applied to the tubes 3 h after inoculation. Colony counts were carried out on liquid samples drawn from the tubes the first day after UVC treatment and liquid and surface samples were collected and analyzed 3-4 days later. A fluence of approximately 1.0 mJ cm(-2) was noted as being sufficient for no growth for a period of 3-4 days for the Teflon tubes. Determining the fluence threshold for the EVA tubes was not possible. Almost all of the UVC-treated EVA tubes were disinfected simply by filling the tubes with a saline solution. Direct UVC treatment of the contaminated EVA tubes revealed, however, that a fluence of 21 mJ cm(-2) killed the bacteria present in the tubes and kept them disinfected for a period of 3-4 days.
منابع مشابه
UVC light prophylaxis for cutaneous wound infections in mice.
UVC light has long been known to be highly germicidal but has not been much developed as a therapy for infections. This study investigated the potential of UVC light for the prophylaxis of infections developing in highly contaminated superficial cutaneous wounds. In vitro studies demonstrated that the pathogenic bacteria Pseudomonas aeruginosa and Staphylococcus aureus were inactivated at UVC l...
متن کاملInactivation of Pseudomonas aeruginosa biofilm after ultraviolet light-emitting diode treatment: a comparative study between ultraviolet C and ultraviolet B.
The objective of this study was to test the inactivation efficiency of two different light-based treatments, namely ultraviolet B (UVB) and ultraviolet C (UVC) irradiation, on Pseudomonas aeruginosa biofilms at different growth stages (24, 48, and 72 h grown). In our experiments, a type of AlGaN light-emitting diodes (LEDs) was used to deliver UV irradiation on the biofilms. The effectiveness o...
متن کاملTime Effectiveness of Ultraviolet C Light (UVC) Emitted by Light Emitting Diodes (LEDs) in Reducing Stethoscope Contamination
Today it is well demonstrated that stethoscopes can be as contaminated as hands, which are a recognized source of Health-Care Associated Infections (HCAIs). Ultraviolet C (UVC) light has proven disinfection capacity and the innovative UVC technology of Light Emitting Diode (LED) shows several potential benefits. To verify whether the use of UVC LEDs is effective and reliable in stethoscope memb...
متن کاملUse of immunogenic moiety of Pseudomonas aeruginosa exotoxin A as a DNA vaccine in experimentally contaminated mice
Background: DNA immunization is an appropriate method to produce an immunological response. Pseudomonas aeruginosa produces exotoxin A which is highly cytotoxic for eukaryotic cells. Since domains II (translocation domain) and 1b of the toxin have antigenic qualities, so they could be useful candidates to protect against pseudomonas infections. Objectives: To evaluate if recombinant plasmid co...
متن کاملIsolation and characterization of diesel-degrading Pseudomonas strains from diesel-contaminated soils in Iran (Fars province)
In this study, among the 21 diesel-degrading bacteria that were isolated from an oil-polluted area in Fars (Iran), 6 bacterial strains were tested for their capability to metabolize and grow on diesel oil by degrading its hydrocarbons content. The biochemical characteristics and 16S rRNA sequence analysis of diesel-degrading bacteria showed that these strains were related to the genus Pseudomon...