Energy distribution between distance and near images in apodized diffractive multifocal intraocular lenses.

نویسندگان

  • Fidel Vega
  • Francisco Alba-Bueno
  • María S Millán
چکیده

PURPOSE To determine the energy distribution between the distance and near images formed in a model eye by spherical and aspheric apodized diffractive multifocal intraocular lenses (IOLs). METHODS The IOL was inserted in a model eye with an artificial cornea with positive spherical aberration (SA) similar to that of the human cornea. The energy of the distance and near images, as a function of the pupil size, was experimentally obtained by image analysis. The level of SA on the IOL, which is pupil-size-dependent, was determined from simulations. The influence of the SA was deduced from results obtained in monofocal IOLs and by comparison of the experimentally obtained energy efficiency to theoretical results based solely on the diffractive profile of the IOL. RESULTS In contrast with theoretical predictions, the energy efficiency of the distance image strongly decreased for large pupils, because of the high level of SA in the IOL. The decrease was smaller in the apodized diffractive multifocal lens with aspheric design. As for the near image, since the diffractive zone responsible for the formation of this image was the same in the spherical and aspheric lenses and the apertures involved were small (and so the level of SA), the results turned out to be similar for both designs. CONCLUSIONS For large pupils, the energy efficiency of the distance image is strongly affected by the level of SA, although aspheric IOLs perform slightly better than their counterparts with a spherical design. For small pupils, there are no differences between the spherical and aspheric IOLs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy balance in apodized diffractive multifocal intraocular lenses

The energy distribution between the distance and near images formed in a model eye by three different apodized diffractive multifocal intraocular lenses (IOLs) is experimentally determined in an optical bench. The model eye has an artificial cornea with positive spherical aberration (SA) similar to human cornea. The level of SA upon the IOL, which is pupil size dependent, is controlled using a ...

متن کامل

Comparative visual performance with monofocal and multifocal intraocular lenses

BACKGROUND To compare near, intermediate, and distance vision, and quality of vision using appropriate subjective questionnaires, when monofocal or apodized diffractive multifocal intraocular lenses (IOLs) are binocularly implanted. METHODS Patients with different binocular IOLs implanted were recruited after surgery and had their visual acuity tested, and quality of vision evaluated, at a si...

متن کامل

Multifocal IOLs with apodized diffractive central zone and refractive periphery: optical performance and clinical outcomes

The apodized diffractive multifocal intraocular lens is one of the intraocular lens types currently available for the correction of presbyopia. The design of apodized diffractive multifocal intraocular lenses improves on the visual outcomes obtained with the full optic diffractive and refractive intraocular lenses. In addition to the visual improvements, apodized diffractive multifocal intraocu...

متن کامل

[Halos and multifocal intraocular lenses: origin and interpretation].

OBJECTIVE To present the theoretical and experimental characterization of the halo in multifocal intraocular lenses (MIOL). METHOD The origin of the halo in a MIOL is the overlaying of 2 or more images. Using geometrical optics, it can be demonstrated that the diameter of each halo depends on the addition of the lens (ΔP), the base power (P(d)), and the diameter of the IOL that contributes to...

متن کامل

A Contralateral Eye Study Comparing Apodized Diffrative and Full Diffrative Lenses: Wavefront Analysis and Distance and Near Uncorrected Visual Acuity

PURPOSE To evaluate intraindividual visual acuity, wavefront errors and modulation transfer functions in patients implanted with two diffractive multifocal intraocular lenses. METHODS This prospective study examined 40 eyes of 20 cataract patients who underwent phacoemulsification and implantation of a spherical multifocal ReSTOR intraocular lens in one eye and an aspheric Tecnis ZM900 multif...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 8  شماره 

صفحات  -

تاریخ انتشار 2011