A Microwave Gyro Amplifier With a Ferroelectric Cathode

نویسندگان

  • Moshe Einat
  • Eli Jerby
  • Gil Rosenman
چکیده

A ferroelectric cathode is employed for the first time as the electron-beam source in a microwave amplifier tube. A PLZT 12/65/35 ferroelectric ceramic with a high dielectric constant ( 4000) is used in a form of a hollow cathode. The tube is operated in poor vacuum conditions (2 10 Torr) at room temperature, in a mechanism of a cyclotron-resonance maser amplifier. The device operates near the waveguide cutoff frequency at 6927 MHz. A 22-dB electronic gain and a 25-W output power are measured in this experiment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Twt Amplifier Using a Ferroelectric Cathode for Electron Beam Generation

We report first experiments on high-power traveling wave amplifiers using an electron beam generated with a ferroelectric cathode. The electron beam, which is driven by a ferrite core transformer-pulse line system, has energy of 440 keV and a beam current of 40-50 Amperes. The beam pulse duration is about 250 ns and the system is operated at 0.07 Hz. The beam is generated from a command switche...

متن کامل

High-Power Microwave Generation Using A Ferroelectric Cathode Electron Gun

A two-stage 500 kV 200-A ferroelectric electron gun has been designed, fabricated, tested, and used in a high power microwave amplifier experiment. We report on the operational characteristics of the gun including measurements of the beam dynamics. The optimum conditions for application of the trigger and its timing are also reported. Faraday cup measurement shows that the beam radius is 4.1 mm...

متن کامل

High-repetition-rate ferroelectric-cathode gyrotron

The intensive research on ferroelectric electron-emission mechanisms in the last decade has resulted in a wide understanding of the physics and characteristics of this plasma-assisted electron source. Nevertheless, practical devices employing this cathode were hardly introduced. In this experimental study, a high-repetition-rate microwave oscillator based on a ferroelectric electron gun has bee...

متن کامل

Kiloampere and Microsecond Electron Beams from Ferroelectric Cathodes

We report experimental results of the operation of two ferroelectric cathodes of relatively large size. The first cathode had a diameter of 10.2 cm and was built in the Pierce cathode geometry by Integrated Applied Physics (IAP). It achieved emission currents of up to 1.2 kA (15.3 A/cm 2) at voltages upto 100 kV, in 150 ns pulses. The second cathode had an annular shape with a diameter of 11.4 ...

متن کامل

Energy coupling in a diode with a die

Among the various electron emission mechanisms the emission using ferroelectric ceramics is the ‘‘junior’’ process. It was observed at very low current density levels ~10 pA/cm! in 1984 by Rosenman. Five years later, Riege and his co-workers at CERN demonstrated current densities that are 13 orders of magnitude higher. In 1990 Airapetov reported the highest current density so far when measuring...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001