Measurements of detector nonlinearity at 193 nm.
نویسندگان
چکیده
We have developed a measurement system based on a correlation method to characterize the nonlinearity of a detector's response over a large range of laser pulse energy. The system consists of an excimer-laser source, beam-shaping optics, a beam splitter, a monitor detector, a set of optical filters, and the detector under test. Detector nonlinearities as large as 10% or greater over an entire measurement range at an excimer-laser wavelength of 193 nm are observed. The measurement range of the current system is approximately 300 nJ to 50 mJ of laser pulse energy at the detector under test. The typical expanded measurement uncertainty of nonlinearity is 0.6% (k = 2).
منابع مشابه
Removing nonlinearity of a homodyne interferometer by adjusting the gains of its quadrature detector systems.
Most homodyne interferometers have a quadrature detector system that includes two polarizing beam splitters that cause nonlinearity of the order of a few nanometers by phase mixing. Detectors should have the same gains to reduce nonlinearity under the assumption that there is no loss in optical components. However, optical components exhibit some loss. We show that nonlinearity can be reduced t...
متن کاملNonlinearity Measurements of High-Power Laser Detectors at NIST
We briefly explain the fundamentals of detector nonlinearity applicable to both electrical and optical nonlinearity measurements. We specifically discuss the attenuation method for optical nonlinearity measurement that the NIST system is based upon, and we review the possible sources of nonlinearity inherent to thermal detectors used with high-power lasers. We also describe, in detail, the NIST...
متن کاملLaser Ablation Inductively Coupled Plasma
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is one of the most successful direct solid sampling techniques for major, minor and trace element analysis. However, this technique still suffers from matrix dependent ablation characteristics, which makes quantification very difficult. Furthermore, the laser sampled material alters its composition from the sample to the de...
متن کاملDNA Damage Induced by 193-nm Radiation in Mammalian Cells1
The contribution of DNA damage to the effects of 193-nm excimer laser radiation on mammalian cells in culture was studied in order to evaluate the mutagenic potential of this IV wavelength in vivo. Two approaches were taken: measurement of pyrimidine dimer-specific endonuclease-sensitive sites/megabase and comparison of the 193-nm ra diation-induced cytotoxicity in normal versus DNA repair-defi...
متن کاملDNA damage induced by 193-nm radiation in mammalian cells.
The contribution of DNA damage to the effects of 193-nm excimer laser radiation on mammalian cells in culture was studied in order to evaluate the mutagenic potential of this UV wavelength in vivo. Two approaches were taken: measurement of pyrimidine dimer-specific endonuclease-sensitive sites/megabase and comparison of the 193-nm radiation-induced cytotoxicity in normal versus DNA repair-defic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 44 6 شماره
صفحات -
تاریخ انتشار 2005