Kinetic and kinematic responses of post mortem human surrogates and the Hybrid III ATD in high-speed frontal sled tests.
نویسندگان
چکیده
Despite improvements in vehicle design and safety technologies, frontal automotive collisions continue to result in a substantial number of injuries and fatalities each year. Although a considerable amount of research has been performed on PMHSs and ATDs, matched dynamic whole-body frontal testing with PMHSs and the current ATD aimed at quantifying both kinetic and kinematic data in a single controlled study is lacking in the literature. Therefore, a total of 4 dynamic matched frontal sled tests were performed with three male PMHSs and a Hybrid III 50th percentile male ATD (28.6g, Δv=40 kph). Each subject was restrained using a 4 kN load limiting, driver-side, 3-point seatbelt. Belt force was measured for the lap belt and shoulder belt. Reaction forces were measured at the seat pan, seat back, independent foot plates, and steering column. Linear head acceleration, angular head acceleration, and pelvic acceleration were measured for all subjects. Acceleration of C7, T7, T12, both femurs, and both tibias were also measured for the PMHSs. A Vicon motion analysis system, consisting of 12 MX-T20 2 megapixel cameras, was used to quantify subject 3D motion (±1 mm) at a rate of 1 kHz. Excursions of select anatomical regions were normalized to their respective initial positions and compared by test condition and between subject types. Notable discrepancies were observed in the responses of the PMHSs and the ATD. The reaction forces and belt loading for the ATD, particularly foot plate, seat back, steering column, and lap belt forces, were not in agreement with those of the PMHSs. The forward excursions of the ATD were consistently within those of the PMHSs with the exception of the left upper extremity. This could potentially be due to the known limitations of the Hybrid III ATD shoulder and chest. The results presented herein demonstrate that there are some limitations to the current Hybrid III ATD under the loading conditions evaluated in the current study. Overall, this study presents a comprehensive data set of belt forces, reaction forces, accelerations, and bilateral displacement data that can be used to evaluate the performance of ATDs and validate computational models.
منابع مشابه
Kinematic Comparison of Pediatric Human Volunteers and the Hybrid III 6-Year-Old Anthropomorphic Test Device.
The Hybrid III 6-year-old ATD has been benchmarked against adult-scaled component level tests but the lack of biomechanical data hinders the effectiveness of the procedures used to scale the adult data to the child. Whole body kinematic validation of the pediatric ATD through limited comparison to post mortem human subjects (PMHS) of similar age and size has revealed key differences attributed ...
متن کاملRear seat occupant safety: an investigation of a progressive force-limiting, pretensioning 3-point belt system using adult PMHS in frontal sled tests.
Rear seat adult occupant protection is receiving increased attention from the automotive safety community. Recent anthropomorphic test device (ATD) studies have suggested that it may be possible to improve kinematics and reduce injuries to rear seat occupants in frontal collisions by incorporating shoulder-belt force-limiting and pretensioning (FL+PT) technologies into rear seat 3-point belt re...
متن کاملOccupant kinematics in low-speed frontal sled tests: Human volunteers, Hybrid III ATD, and PMHS.
A total of 34 dynamic matched frontal sled tests were performed, 17 low (2.5g, Δv=4.8kph) and 17 medium (5.0g, Δv=9.7kph), with five male human volunteers of approximately 50th percentile height and weight, a Hybrid III 50th percentile male ATD, and three male PMHS. Each volunteer was exposed to two impulses at each severity, one relaxed and one braced prior to the impulse. A total of four test...
متن کاملInjury risk of a 6-year-old wheelchair-seated occupant in a frontal motor vehicle impact--'ANSI/RESNA WC-19' sled testing analysis.
Children with disabilities are transported on a daily basis to schools and developmental facilities. When they travel, they often remain seated in their wheelchairs in vehicles. To study injury risk of pediatric wheelchair users in motor vehicle crashes, three of the same pediatric manual wheelchairs were sled impact tested with a seated Hybrid III 6-year-old ATD using a 20 g/48 km/h frontal cr...
متن کاملThe effects of tethering rear -facing child restraint systems on ATD responses.
A series of sled tests was performed to analyze the responses of an anthropomorphic test device (ATD), particularly neck forces, when rear-facing child restraint systems (CRS) are tethered. Nominally identical rear-facing CRS were tested in four tether conditions: untethered, tethered down to the floor, tethered down to the bottom of the vehicle seat, and tethered rearward to a point above the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Accident; analysis and prevention
دوره 55 شماره
صفحات -
تاریخ انتشار 2013