Operative treatment of intra-articular distal radius fractures using the small AO external fixation device.

نویسندگان

  • Teng-Le Huang
  • Ching-Kuei Huang
  • Jung-Kuang Yu
  • Fang-Yao Chiu
  • Hsing-Torng Liu
  • Chien-Lin Liu
  • Tain-Hsiung Chen
چکیده

BACKGROUND A retrospective group study was done to evaluate the effect of the small AO external fixator in the management of acute intra-articular fractures of the distal radius. METHODS Between January 1995 and December 1996, 70 consecutive patients with articular fractures of the distal radius were treated by closed reduction and external fixation with small AO external fixators. The mean age at the time of surgery was 58.9 years (range, 14-87 years). There were 58 Colles' Barton's fractures and 12 Smith's Barton's fractures. The follow-up period was 104 months (range, 92-118 months). RESULTS All fractures united in a mean of 5.8 weeks (range, 4-10 weeks). At the final follow-up, the average range of motion was 56.3 +/- 11.6 degrees in flexion, 58.6 +/- 10.7 degrees in extension, 21.5 +/- 4.2 degrees in ulnar deviation, 9.1 +/- 2.9 degrees in radial deviation, 71.5 +/- 8.5 degrees in pronation, and 67.3 +/- 9.2 degrees in supination. Compared with the normal side, the average grip force was 87 +/- 6%. The overall clinical and functional outcomes, according to the scoring system of Gartland and Werley, showed that 22 patients (31.4%) had excellent results, 36 (51.4%) had good results, 9 (12.9%) had fair results, and 3 (4.3%) had poor results. CONCLUSION Closed reduction and external fixation with the small AO external fixator is useful and effective in the management of displaced comminuted articular fractures of the distal radius.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

External fixation for the treatment of intra-articular fractures of the distal radius: short-term results.

BACKGROUND There is controversy as to which is the preferred treatment for distal radius intra-articular fractures--anatomic reduction or external fixation. OBJECTIVES To evaluate the radiologic and functional outcome following external fixation of these fractures. METHODS Between January 2003 and March 2005, 43 patients with distal radius intra-articular fractures were treated using a mini...

متن کامل

Intra-articular Fractures of Distal Radius; Outcome of Treated with Bridging (static) External Fixator

..Objective: To assess the radiological and functional outcome of external fixator in the treatment of intar-articular fractures of distal radius. Study design: Descriptive case series. Place and duration of study: Orthopaedic unit District Headquarter Hospital Temargarha Lower Dir from March 2013 to March 2014. Material and methods: Twenty five patients of intra-articular fracture distal radiu...

متن کامل

Nonbridging external fixation of intra-articular distal radius fractures.

New solutions to difficult problems are always welcome, but nonbridging external fixation of intra-articular fractures is still in its infancy. Multicenter clinical trials are necessary to deter-mine whether the superior results obtained with nonbridging fixation of extra-articular fractures can be duplicated. With further study and new fixator designs, it is anticipated that nonbridging extern...

متن کامل

Internal plate fixation versus plaster in displaced complete articular distal radius fractures, a randomised controlled trial

BACKGROUND Of all distal radius fractures, 25 % are complete articular fractures (AO/OTA type C fractures). Two thirds of those fractures are displaced and require reduction. According to several International Guidelines, adequately reduced intra-articular distal radius fractures are best treated non-operatively with plaster immobilisation, while surgical fixation is suggested only when the art...

متن کامل

Complications and functional outcome following fixation of complex, intra-articular fractures of the distal radius with the AO Pi-Plate.

This study investigates the efficacy of the AO Pi-plate in the treatment of complex, intra-articular fractures of the distal radius. We retrospectively analysed the clinical and radiological results of 19 consecutive patients who underwent open reduction and internal fixation for dorsally displaced, intra-articular fractures of the distal radius using the AO Pi-plate. The final functional outco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Chinese Medical Association : JCMA

دوره 68 10  شماره 

صفحات  -

تاریخ انتشار 2005