Comparison of heat generation between internally guided (cannulated) single drill and traditional sequential drilling with and without a drill guide for dental implants.

نویسندگان

  • Scott E Bulloch
  • Russell G Olsen
  • Brandon Bulloch
چکیده

PURPOSE To determine whether a wire-guided single drill protocol could be utilized without causing an increase in bone temperature beyond those seen with the traditional techniques of sequential drilling with and without a drill guide. MATERIALS AND METHODS A bovine femoral bone model was used with thermocouples and infrared temperature measurements to record thermal increase of the bone and drills during implant site preparation. Two thermocouples, one on each side of the osteotomy, were placed 1 mm from the outer diameter of the final drill. Drilling was performed at a constant speed (2,100 rpm) and pressure (2 kg) under continuous room temperature irrigation. Infrared temperature measurements of each drill were taken immediately before and after drilling. The six study groups included standard sequential drilling protocols for 3.5-mm and 4.2-mm final drills with and without the use of a surgical guide, and cannulated single drill technique for 3.5-mm and 4.2-mm drills. Statistical analysis was performed using a Tukey post hoc one-way ANOVA test. P<.05 was determined to be significant. RESULTS No significant difference in thermal increase was found between single drill cannulated implant site preparation and sequential drilling with or without the use of a drill guide for the 3.5-mm or 4.2-mm drilling sequences, respectively. The thermal increase was found to be significantly less for the 4.2-mm single drill compared with the 3.5-mm sequential drill with surgical guide (P=.046). Infrared temperature measurement revealed no significant difference in drill temperatures throughout the study. CONCLUSIONS Cannulated single drill technique does not cause an increase in bone temperature greater than that seen with standard sequential drilling with or without a surgical guide.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

FEM investigation of drilling conditions on heat generation during teeth implantation

Abstract The first step of implanting teeth is to drill a hole in the jaw bone. Excessive temperature produced during drilling is one of the destructive factors for bony tissue. If the temperature generation during surgical drilling exceeds the critical temperature, it could lead to osteonecrosis. This research intends to study drilling parameters such as drilling speed, feed rate, cooling con...

متن کامل

The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability.

PURPOSE The authors evaluated, under conditions simulating implant placement, the cutting efficiency, durability, heat production, and wear of implant drills. MATERIALS AND METHODS Osteotomies were performed on bovine ribs using a surgical unit mounted in a testing apparatus. A software program controlled the apparatus and recorded temperatures, depths, and drilling times. Seven brands of dri...

متن کامل

A Comparison of Heat Generation in Different Depths of Implant Drilling Site with and without a Sleeve

Introduction: The purpose of this study was to compare the heat generated from different depths of an implant drilling site with and without a sleeve. Materials and methods: In this study, 60 cortical bone samples were used and a load of 2.0 kg was applied. rilling for implant surgery, we used a diameter of 4.3 mm and a normal sleeve. Heat was measured from 3 different depths(3,6, an...

متن کامل

Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites - thermographic analysis on bovine ribs.

Background/Aim During drilling implant sites, mechanical energy is converted into thermal one resulting in transient rise in temperature of surrounding bone. The temperature of 47°C exeeding one minute impairs osseointegration, compromises mechanical properties of the local bone and could cause early implant failure. This in vitro study aimed to assess the effect of surgical drill guide and tem...

متن کامل

A new thermal model for bone drilling with applications to orthopaedic surgery.

This paper presents a new thermal model for bone drilling with applications to orthopaedic surgery. The new model combines a unique heat-balance equation for the system of the drill bit and the chip stream, an ordinary heat diffusion equation for the bone, and heat generation at the drill tip, arising from the cutting process and friction. Modeling of the drill bit-chip stream system assumes an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 27 6  شماره 

صفحات  -

تاریخ انتشار 2012