Sequential dispersive liquid-liquid microextraction for the determination of aryloxyphenoxy-propionate herbicides in water.

نویسندگان

  • Songqing Li
  • Peng Gao
  • Jiaheng Zhang
  • Yubo Li
  • Bing Peng
  • Haixiang Gao
  • Wenfeng Zhou
چکیده

A novel dispersive liquid-liquid microextraction (DLLME) method followed by HPLC analysis, termed sequential DLLME, was developed for the preconcentration and determination of aryloxyphenoxy-propionate herbicides (i.e. haloxyfop-R-methyl, cyhalofop-butyl, fenoxaprop-P-ethyl, and fluazifop-P-butyl) in aqueous samples. The method is based on the combination of ultrasound-assisted DLLME with in situ ionic liquid (IL) DLLME into one extraction procedure and achieved better performance than widely used DLLME procedures. Chlorobenzene was used as the extraction solvent during the first extraction. Hydrophilic IL 1-octyl-3-methylimidazolium chloride was used as a dispersive solvent during the first extraction and as an extraction solvent during the second extraction after an in situ chloride exchange by bis[(trifluoromethane)sulfonyl]imide. Several experimental parameters affecting the extraction efficiency were studied and optimized with the design of experiments using MINITAB® 16 software. Under the optimized conditions, the extractions resulted in analyte recoveries of 78-91%. The correlation coefficients of the calibration curves ranged from 0.9994 to 0.9997 at concentrations of 10-300, 15-300, and 20-300 μg L(-1). The relative SDs (n = 5) ranged from 2.9 to 5.4%. The LODs for the four herbicides were between 1.50 and 6.12 μg L(-1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection

A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...

متن کامل

Ion Pair Dispersive Liquid-Liquid Microextraction for the Determination of Trace Amounts of Copper(II) in Soil, Multivitamin Tablet, Tea and Water Samples Using Flame Atomic Absorption Spectrometry

Ion pair dispersive liquid- liquid microextraction (IP-DLLME) method combined with flame atomic absorption spectrometry was proposed for the determination of trace amounts of copper(II). By using pyrocatechol violet as chelating agent and cetyltrimethyl ammonium bromide as an ion pairing agent, the trace amount of copper(II) was extracted in chloroform. The factors influencing the formation cop...

متن کامل

A New Dispersive Liquid-Liquid Microextraction Method Followed by Direct GF-AAS Determination Optimized with Experimental Design and Response Surface Methodology for Determination of Ag(I) in Water Samples

In this research, a rapid, reliable and selective dispersive liquid-liquid microextraction (DLLME) followed by direct injection of microdroplet to graphite furnace atomic absorption spectrometry (GF-AAS) method for the determination of ultra-trace amounts of Ag(I) was developed. Effect of the important experimental parameters on the extraction efficiency of Ag(I) was investigated using response...

متن کامل

Preconcentration based dispersive liquid-liquid microextraction for spectrophotometric determination of zinc in natural water and human blood after multivariate optimization based on Box-Behnken design

A new simple and rapid dispersive liquid-liquid microextraction has been applied to preconcentrate tracelevels of zinc as a prior step to its determination by spectrophotometric method. In the proposed method, 4-(2-pyridylazo) resorcinol (PAR) is used as a chelating agent, and chloroform and ethanol are selected asextraction and dispersive solvent. The optimization strategy is carried out by us...

متن کامل

Preconcentration and Speciation of Chromium Using Dispersive Liquid-Liquid Microextraction; Application to Milk and Different Water Samples

A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) was developed for determination and speciation of trace amounts of chromium (Cr) by flame atomic absorption spectrometry (FAAS). In the proposed approach, chloroform and methanol were used as extraction and dispersive solvents. A new Schiff's base ligand, bis(2-methoxy benzaldehyde) ethylene d...

متن کامل

ذخیره در منابع من