Re: Three-dimensional analysis of alignment error in using femoral intramedullary guides in unicompartmental knee arthroplasty.

نویسنده

  • Srinivasa Sridhar
چکیده

We used computerized simulations with 3-dimensional models of 20 cadaver femora, calculated from computed tomographic scans, and a model of a rod measuring 200 x 5 mm to study femoral alignment accuracy for unicompartmental knee arthroplasty via minimally invasive reconstruction. The anatomical axis and insertion site were identified on each femur. A simulation of all feasible flexion-extension and varus-valgus orientations was performed. The average rod orientation was 3.2 degrees flexion and 2.5 degrees valgus. The range of orientation was 3.2 degrees extension to 9.7 degrees flexion and 4.5 degrees varus to 8.9 degrees valgus. The study suggests that a short narrow intramedullary rod inserted according to the manufacturer's specifications does not accurately find the anatomical axis and may lead to poor alignment of the femoral prosthesis. Given our finding of consistent bias toward excessive flexion and valgus alignment, we recommend that the operating surgeon carefully plan the insertion point of the intramedullary rod during surgery to compensate for this bias.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Different References for Valgus Cut Angle in Total Knee Arthroplasty

Background: The valgus cut angle (VCA) of the distal femur in Total Knee Arthroplasty (TKA) is measured preoperativelyon three-joint alignment radiographs. The anatomical axis of the femur can be described as the anatomical axis of thefull length of the femur or as the anatomical axis of the distal half of the femur, which may result in different anglesin some cases. During TKA, the anatomical ...

متن کامل

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation

Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...

متن کامل

Unicompartmental Knee Osteoarthritis (UKOA): Unicompartmental Knee Arthroplasty (UKA) or High Tibial Osteotomy (HTO)?

  Background: The aim of this review article is to analyze the results of high tibial osteotomy compared to unicompartmental knee arthroplasty in patients with unicompartmental knee osteoarthritis.   Methods: The search engine used was PubMed. The keywords were: "high tibial osteotomy versus unicompartmental knee arthroplasty". Twenty-one articles were found on 28 February 2015, but only eighte...

متن کامل

Extramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement

BACKGROUND In a standard total knee replacement, tibial component alignment is a key factor for the long term success of the surgery. The purpose of this study is to compare the accuracy of extramedullary and intramedullary tibial cutting guides used in indigenous and imported implants respectively, in positioning of the tibial components in megaprosthetic knee replacements. METHODS A compara...

متن کامل

Distal Femoral Valgus Cut Errors in Total Knee Replacement

The causes of malalignment in total knee arthroplasty can be categorized into three different groups; 1) Errors in bone cuts 2) Errors in implant fixations, and 3) The method of setting down the cutting guides (1). We would like to announce that more several distal femoral valgus cut errors may occur during total knee replacement.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 21 8  شماره 

صفحات  -

تاریخ انتشار 2006